Vulcan-Hart ML-126883 Installation Codes And Standards, In the United States of America, Assembly

Models: GPC12S ML-126883 ML-126881 GPC12

1 20
Download 20 pages 29.23 Kb
Page 6
Image 6
INSTALLATION CODES AND STANDARDS

INSTALLATION CODES AND STANDARDS

Your Vulcan-Hart gas pasta cooker must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from the American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.

3.National Electrical Code ANSI/NFPA-70 (latest edition). Copies may be obtained from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.CAN/CGA-B149.1 (latest edition) Natural Gas Installation Code.

3.CAN/CGA-B149.2 (latest edition) Propane Installation Code, available from the Canadian Standards Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.

4.Canadian Electric Code, CSA Standard C22.2 No.3 (latest edition). Copies may be obtained from The Canadian Standards Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.

ASSEMBLY

The cooker must be restrained to prevent tipping when installed in order to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the cooker in an alcove, or by separate means, such as adequate ties.

Legs

1.Position the pasta cooker in an open space near the final installation area.

2.Tilt pasta cooker on its side. Be careful not to scratch the finish.

3.Thread legs into mounting holes provided on the bottom of the pasta cooker by screwing in a clockwise rotation until tightened.

4.Carefully raise pasta cooker to its normal position and place it in the installing location.

– 6 –

Page 6
Image 6
Vulcan-Hart ML-126883, GPC12 Installation Codes And Standards, In the United States of America, In Canada, Assembly, Legs