Carrier 50KQL-1PD manual Field-installed accessories

Models: 50KQL-1PD

1 36
Download 36 pages 56.94 Kb
Page 7
Image 7
Field-installed accessories

50KQL CONTROL OPTIONS TABLE

OPTION

 

CONTROLLER

THERMOSTAT

FUNCTIONS

TRANSFORMER

 

A

 

Complete C

MCO

50 VA

 

B

 

Deluxe D

MCO

NIGHT LOW LIMIT 2-HR OVERRIDE

75 VA

 

C

 

Complete C

ACO

50 VA

 

D

 

Deluxe D

ACO

NIGHT LOW LIMIT 2-HR OVERRIDE

75 VA

 

P

 

Complete C with PremierLink™

LINKAGE

DDC SYSTEM

50 VA

 

R

 

Complete C

REMOTE

50 VA

 

S

 

Deluxe D

REMOTE

NIGHT LOW LIMIT2-HR

75 VA

 

 

OVERRIDE

 

 

 

 

 

 

 

LEGEND

 

 

 

ACO

Auto Changeover

 

 

 

DDC

Direct Digital Controls

 

 

 

MCO

Manual Changeover

 

 

 

Field-installed accessories

Carrier’s line of Aquazone™ thermostats (used with remote thermostat units) are both attractive and multi- functional, accommodating stand-alone water source heat pump installations.

Programmable 7-day thermostat — Offers 2-stage heat, 2-stage cool, auto changeover, 7-day programmable with copy command, 4 settings per day, fully electronic, 24 vac, backlit LCD, keypad lockout, no batteries required, 5-minute compressor protection, NEVERLOST™ memory, 3 security levels, temperature display in degrees F or C.

Programmable 7-daylight-activated thermostat — Offers same features as the 7-day programmable thermostat and includes occupied comfort settings with lights on, unoccu- pied energy savings with lights off.

Programmable 7-dayflush-mount thermostat — Offers same features as the 7-day programmable thermostat and includes locking coverplate with tamper proof screws, flush to wall mount, holiday/vacation programming, set point limiting, dual point with adjustable deadband, O or B termi- nal, and optional wall or duct-mounted remote sensor.

Programmable 5-day thermostat — Offers 2-stage heat, 2-stage cool, auto changeover, 5-minute built-in compres- sor protection, locking cover included, temperature display in degrees F or C, keypad lockout, backlit display, 5-1-1 programming, O or B terminal, dual set point with adjust- able deadband, configurable display, self-prompting pro- gram, 4 settings per day.

Non-programmable thermostat — Offers 2 heat stages, 2 cool stages, auto changeover, 5-minute built in compressor protection, locking cover included, temperature display in degrees F or C, keypad lockout, large display, back-lit dis- play, O or B terminal, dual set point with adjustable dead- band, backplate with terminals.

Aquazone system control panel includes a pre- programmed, easy to use, Carrier Comfort Controller set up for a WSHP system.

Coordinates, monitors, and controls all WSHP units and ancillary equipment including cooling towers, boil- ers, and system pumps.

50RLP model nomenclature is used to customize the panel to control all WSHP system requirements.

Panel can be ordered to include 2, 4, 6, or 8 stages of system heat rejection.

Panel can be ordered to include 2, 4, 6, or 8 stages of system heat addition.

Panel can be ordered with unique WSHP zone operation capabilities for stand alone systems (i.e., non-communicating) to control 10 or 18 zones of WSHP units.

Panel can be ordered to control variable frequency cool- ing tower fan operation.

System pumping operation can be configured for start/ stop, lead/lag, or variable frequency pump operation.

Direct Digital Control compatible using the Carrier Comfort Network (CCN) and WSHP units utilizing PremierLink CCN controllers.

Fire-rated hoses are 2 ft long and have a fixed MPT on one end and a swivel with an adapter on the other end. Hose kits are provided with both a supply and return hose and can be either stainless steel or galvanized. Five sizes are available (1/2, 3/4, 1, 11/4, 11/2 in.).

Ball valves (brass body) used for shutoff and balancing water flow. Available with memory, memory stop, and pressure temperature ports. UL-listed brass body, ball and stem type with Teflon seats and seals. Five sizes are avail- able (1/2, 3/4, 1, 11/4, 11/2 in.).

Y strainers (bronze body) are “Y” type strainers with

a

brass cap. Maximum operating pressure rating

of

450 psi. Strainer screen made of stainless steel. Available with blow down valves. Five sizes are available (1/2, 3/4, 1, 11/4, 11/2 in.).

Solenoid valves (brass body) offer 3.5 watt coil, 24 volt, 50/60 Hz, 740 amps inrush, .312 amps holding. Slow operation for quiet system application. Five sizes are available (1/2, 3/4, 1, 11/4, 11/2 in.).

Hose kit assemblies provide all the necessary compo- nents to hook up a water-side system. Supply hose includes a ported ball valve with pressure temperature (P/T) plug ports, flexible stainless steel hose with swivel and nipple. Return hose includes a ball valve, preset auto- matic balancing valve (gpm) with two P/T ports, flexible stainless steel hose with a swivel and nipple, balancing valve, and low-pressure drop water control valve.

Remote sensors are available for Aquazone flush mount thermostats. Sensors are available for wall (wired and wire- less) or duct mounted applications.

PremierLink™ accessories are available to provide a fully integrated WSHP DDC system. Accessories include supply air temperature sensors (with override and/or set- point adjustment), communicating room sensors, CO2 sen- sors (for use in demand control ventilation), and linkage thermostats (to control multiple units from one thermostat).

7

Page 7
Image 7
Carrier 50KQL-1PD manual Field-installed accessories