Quiet operation
The Carrier Console WSHP provides exceptionally quiet operation for maxi- mum comfort.
Design flexibility
Aquazone™ Console WSHP units are offered in 5 capacity sizes and 3 differ- ent voltages to meet individual zone needs efficiently and effectively. Standard and extended operating range units are available to suit a variety of application requirements.
Safe, reliable operation
Standard safety features include: high and low pressure monitoring and field selectable water and air coil freeze pro- tection sensing. All safety controls may be reset at the thermostat. Each unit is tested and run at the factory to ensure proper operation of all components and safety switches.
All components are carefully designed and selected for endurance, durability, and carefree
The
Units are rated and certified in accordance with ARI/ISO/ASHRAE
Installation ease
The unit is packaged for simple, low cost handling, with minimal time re- quired for installation. The console unit
arrives at the jobsite fully assembled to minimize installation time and reduce installation cost. All units are
Water connections are available in a variety of configurations direct from the factory. The standard configuration is 5/8 in. OD Sweat connections for maximum flexibility in the field. Both FPT and MPT are available as factory- installed options to improve installation efficiency. Additionally, factory- installed motorized water shutoff valves are available for use on energy conserving systems employing a variable pumping technique.
The standard electrical connections are made quickly and directly to a pow- er distribution terminal block. To fur- ther improve installation efficiency, a fused or unfused disconnect switch as well as a 20 amp plug and cord are available as
A 5/8 in. ID vinyl condensate con- nection is provided for connection to the
Compact cabinet design dimen- sions are 12 in. deep, 48 in. wide and
24in. tall (with 3 in. subbase). For flex- ibility, the controls can be mounted on the top right or left side. Additionally, the sloped top design discourages the use of the unit as a shelf or coffee hold- er, preventing air blockage and any spills from damaging the unit.
Regular maintenance or service to the console WSHP units require little time. Large service access panels enable
quick inspection for problem solving and the control box swings down for easy access to the controls.
Fan motor sleeve bearings are permanently lubricated for
Refrigerant circuit protection is de- signed to result in fewer service calls. Units are equipped with easily accessi- ble service access ports on both the suction and the discharge refrigerant lines for
Maximum control flexibility
Aquazone water source heat pumps provide reliable control operation using a standard microprocessor board.
Flexible alternatives for many direct digital control (DDC) applications in- clude the Carrier Comfort Network (CCN) and open protocol systems.
Carrier’s Aquazone standard unit
50 va transformer — Assists in accommodating accessory loads.
Table of contents
| Page |
|
|
|
|
Features/Benefits |
|
|
|
| |
Model Number Nomenclature | . . . 4 |
|
|
|
|
ARI/ISO | . . . 5 |
|
|
|
|
Physical Data | . . . 5 |
|
|
|
|
Options and Accessories |
|
|
|
| |
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Dimensions |
|
|
|
| |
Selection Procedure | 14,15 |
| As an ENERGY STAR® Partner, | ||
Performance Data |
| Carrier Corporation has deter- | |||
| mined that this product meets | ||||
Application Data | NRTL/C | the ENERGY STAR guidelines | |||
Electrical Data | . . 24 | for energy efficiency. | |||
|
|
|
| ||
Typical Wiring Schematics |
|
|
|
| |
Typical Piping | . . 32 |
|
|
|
|
Guide Specifications |
|
|
|
|
2