AUTOMATIC CHANGEOVER WITH COMPLETE C CONTROLLER

AUTOMATIC CHANGEOVER WITH COMPLETE C CONTROLLER

GROUND

POWER SUPPLY

REFER TO DATA PLATE

USE COPPER CONDUCTORS ONLY.

SEE NOTE 2

REFER TO DISCONNECT

BOX FOR OPTIONAL

POWER SUPPLY CONNECTION

 

NEUTRAL ON 265V

 

SYSTEMS

L2

RED

2

L1

PB

1

COMPRESSOR

HBLU

S

 

CAP

8

R

 

C

RED 6

RED

C

F

BLK 2

CR

 

 

4

BLK

 

 

 

OPTIONAL

 

L2 (ribbed)

 

2

B (HIGH)

 

GROUND

BRN

CORD

 

 

 

BM

CONNECTION

 

L1 (plain)

YEL

 

 

 

 

 

 

SEE

 

BLK

1

A (LOW)

 

 

 

 

CB*

NOTE 3

 

 

 

BLK

BLK

5

5A RED

 

TRANS

PUSH BUTTON SWITCH ATTRIBUTES

 

 

 

24V

 

ORG

 

 

BLK

6

6A RED

 

 

X = CLOSED

 

 

O = OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230V

 

 

 

7

7A

BLK

 

TERMINALS

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PBS

 

 

 

1A

1B

2A

3A

4A

5A

6A

7A

8A

 

 

 

 

 

 

 

 

 

 

 

 

 

STOP

X

O

O

O

O

O

O

O

O

 

 

 

 

 

 

 

 

 

 

TRANSFORMER PRIMARY

 

FAN ONLY

X

O

O

O

O

X

O

O

O

 

 

 

 

 

 

 

 

 

 

LEAD COLORS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW FAN

X

O

O

X

X

O

X

O

O

 

 

 

SEE

 

1

0

SEE

 

VOLTAGE

LEAD COLOR

 

HIGH FAN

X

O

O

X

X

O

O

X

X

 

 

 

NOTE 7

 

NOTE 7

 

115

WHT

 

 

 

 

 

 

 

 

 

 

 

208

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRN YEL

 

 

230

ORG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

265

BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLU

 

BR

BRG CCG

CC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRN

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRN

 

 

TEST PINS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR2

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

HP 1

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

 

 

 

 

 

 

 

 

 

BR1

 

 

 

BRN

 

SEE

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

NOTE 4

 

2

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JW3

 

 

LOC

 

 

 

 

 

 

 

 

 

 

 

UMT

 

YEL

 

 

 

LOC

 

BRN

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

FP1

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

4 ORG 1

 

 

 

JW2

 

5

 

GRY

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

FP2

 

 

FP1

 

 

 

 

 

 

 

 

 

 

 

YEL

2

ORG

W

 

DIP SWITCH

 

FP16

 

GRY

SEE

 

 

 

 

 

 

 

 

 

 

RED

6

3

O

 

1 PM: DISABLED/

FP27

 

VIO

NOTE 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

ENABLED

 

FP2

 

 

 

 

 

 

 

 

 

 

RED 3A PBS3

 

 

RED

G

 

2 STAGE 2: 2/1

8

 

VIO

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

3 NOT USED

RV 9

 

BRN

 

 

 

 

 

 

 

 

 

 

 

 

5

5A

 

 

 

4 NOT USED

 

RVS

 

 

 

 

 

 

 

 

 

 

 

RED RED

 

BRN

C

 

5 FP1/FP2

10

 

ORG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AL1

JW1 OFF ON FAULTS: 3/1

 

 

NOT USED

 

 

 

 

 

 

 

 

 

 

 

6

6A RED

AL2

 

G

STATUS

CO12

 

YEL

CO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

YEL

A

ALARM

SEE

LED

P2

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

7

7A

 

RELAY

NOTE 6 COMPLETE C

24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MICRO-

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROCESSOR

EH1

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

CAP

 

PB

 

 

 

 

 

DM

 

 

 

 

LOGIC

EH2

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL YEL

ORG BRN

 

 

 

CO

P3

 

 

 

 

 

 

 

 

 

 

 

 

 

BRN

WV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER MOTOR WIRING

 

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT SIZE POLE A

POLE B

 

 

 

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

5

3

 

 

 

 

 

 

 

 

 

 

BR1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09

5

4

 

 

 

 

 

 

 

 

 

 

PBS

 

 

 

 

 

 

 

 

12

4

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

4

3

 

COMPLETE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

4

3

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR2

UMT

 

 

LEGEND

AL

Alarm Relay Contacts

BM

Blower Motor

BR

Blower Relay

CAP

Capacitor

CB

Circuit Breaker

CO

Sensor, Condensate Overflow

CR

Compressor Relay

DM

Damper Motor

FP1

Sensor, Water Coil Freeze Protection

FP2

Sensor, Air Coil Freeze Protection

HP

High-Pressure Switch

JW1

Jumper Wire for Alarm

LOC

Loss of Charge Pressure Switch

PB

Power Terminal Block

PBS

Push Button Switch

PM

Performance Monitor

RVS

Reversing Valve Solenoid

TRANS —

Transformer

UMT

Unit Mounted Thermostat

WV

Water Valve

----------

Field Line Voltage Wiring

 

 

Field Low-Voltage Wiring

>>

Printed Circuit Trace Relay/Contactor Coil

Solenoid Coil

Thermistor

Circuit Breaker

Relay Contacts-N.O.

Switch-Temperature

Switch-High Pressure

Switch-Low Pressure

Ground

Wire Nut

Mate-N-Lock

*Optional wiring.

NOTES:

1.Compressor and blower motor thermally pro- tected internally.

2.All wiring to the unit must comply with local codes.

3.Transformer is wired to 115-V (WHT) lead for 115/1/60 units, 265-V (BRN) lead for 265/1/60 units or 208-V (RED) lead for 208/1/60 units.

For 203/1/60 switch RED and ORG leads at L1 and insulate RED lead.

Transformer is energy limiting or may have cir- cuit breaker.

4.FP1 thermistor provides freeze protection for WATER. When using ANTI-FREEZE solutions, cut JW3 jumper.

5.Typical unit-mounted thermostat wiring shown.

6.24-V alarm signal shown. For dry alarm con- tact, cut JW1 jumper and dry contact will be available between AL1 and AL2.

7.Transformer secondary ground via Complete C board standoffs and screws to control box. (Ground available from top two standoffs as shown.)