SEASONING THE GRIDDLE
Season the griddle to avoid possible surface corrosion before first use, and after every cleaning. Heat griddle to a low temperature
CONTROLS
There is one pilot and one safety valve for every two burners except on the 36” and 60” models. The 36” and 60” models have an odd number of main burners, therefore one of the sets of pilots and safety valves in these models will control only one main burner. The pilot burners are aligned with the safety valve bush buttons and pilot sight holes. The pilot burners are inset 12” from the front panel.
This model features an electric ignition system that is controlled by the power switch. The power switch turns the electric ignition system off and on only. It is recommended that the power switch stay in the ON position while the unit is running. The burners and pilots will continue to work with the power switch in the OFF position until the gas supply to the unit is cut off.
The pilots are monitored by thermocouples and pilot safety valves. If the pilot goes out and the corresponding power switch is in the ON position, the igniter will immediately reignite the pilot. If the pilot does not achieve reignition in a short period of time, the safety valve will
Each 12” section of the griddle is independently controlled by a mechanical
- 7 -