BURNER

HELPFUL HINT – If the unit is attached to a flexible gas line, you can extend the bullet feet out to their fullest extension to raise the griddle and allow yourself more clearance while reaching under the unit. Remember to relevel the unit if you chose to do this.

BURNER

The RRG Series Griddle utilizes U-shaped burners with a single center inlet for every 12 inches of griddle width. Each burner is rated for 27,500 BTU/hr.

BURNER TROUBLESHOOTING Disconnect the electrical power and follow lockout / tagout procedures

BURNER TROUBLESHOOTING

SYMPTOM – ALL BURNERS HAVE A LOWER OR HIGHER FLAME THAN NORMAL. 1. Check gas pressure

SYMPTOM – ONE OR MORE BURNERS HAVE LOWER FLAME LEVEL THAN THE OTHERS.

1.Check gas pressure

2.Check burner orifice for obstructions

3.Adjust burner air shutter

4.Check solenoid valve

SYMPTOM – ONE BURNER HAS A DELAYED IGNITION; A SEVERAL SECOND LAPSE BETWEEN THE INDICATOR LIGHT TURING ON AND WHEN THE BURNER ACTUALLY LIGHTS.

1.Check gas pressure

2.Check that burner locater pin is properly seated with retaining clip attached

3.Check that burner ignition ports, pilot flash tube and pilot burner are all aligned.

4.Check burner shutter adjustment

5.Check pilot flame adjustment

6.Check thermostat, safety ignition module and solenoid valve operation.

BURNER REMOVAL

BURNER REMOVAL Shut off gas supply

1.Remove the back panel

- 15 -