Vulcan-Hart 24RRG, ML-135340-00036 Temperature Probe, Disconnect, electrical power and, follow

Models: 24RRG 36RRG 60RRG 48RRG ML-135342-00060 ML-135339-00024 ML135341-00048 ML-135341-00048 ML-135340-00036

1 22
Download 22 pages 52.4 Kb
Page 8
Image 8
TEMPERATURE PROBE

DisconnectDisconnect the electrical power and follow lockout/tagout procedures

THERMOSTAT REMOVAL

1.Remove the control panel

2.Remove the knob

3.Label and disconnect the wires

4.Remove the thermostat retaining nut on the knob shaft.

5.Reverse procedure to install while being careful to install the thermostat in the same orientation.

TEMPERATURE PROBE

The temperature probe is an embedded K type thermocouple assembly.

498432-A

Disconnect

the

 

 

electrical power and

follow

 

lockout/tagout procedures

 

TEMPERATURE PROBE REMOVAL

1. Remove the control panel

2. Remove the back panel

3. Label and disconnect the lead wires at the temperature controller

4. Unthread the probe retaining nut and remove the probe from the back of the unit.

TEMPERATURE PROBE INSTALLATION

1. Insert lead wires from back of heatshield through to temperature controller.

2. Apply a thin coating of high temp(500° F min. rated),copper based heat transfer and anti-seize compound to the probe tip and retaining nut.

3. Insert probe end into plate socket and hand tighten probe retaining nut.

4. Tighten the probe an additional ½ turn only with a wrench. Over tightening can strip threads and damage probe tip.

- 8 -