6.Close the drain valve and refill the tank with water. Add 1 cup (0.2 L) of vinegar to neutralize alkaline left by the cleaner. Solution level must be between the MIN and MAX level on the fryer tank. Bring the solution to a simmer and allow it to stand for a few minutes.

7.Drain the tank and rinse thoroughly with clear, hot water. All traces of cleaner must be removed. Dry the tank thoroughly.

8.Close the drain valve and add shortening. Follow the FILLING FRY TANK WITH SHORTENING procedure in this manual. If using solid shortening, refer to MELT OPTIONS in this manual.

The fryer is now ready for use.

TROUBLESHOOTING

ALARMS AND ERROR MESSAGES

Open Probe - If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

1ERD Models -

Prob

1ERC Models -

OPEN PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem persists, call service.

Shorted Probe - If a shorted probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

1ERD Models - Hi

1ERC Models - SHORTED PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem persists, call service.

Hi Temperature - If the temperature is greater than or equal to 415°F (212°C), the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

1ERD Models - Hi

1ERC Models - SHORTED PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. Normal fryer operations resumes when temperature drops below 415°F (212°C). If the problem persists, call service.

Display Flashing "FILTER" - When the display flashes FILTER, the countdown timer has reached zero. Refer to the Filter Programming procedure in this manual to reset the timer.

1ERC Models - FILTER

— 19 —

Page 19
Image 19
Vulcan-Hart ML-136496, ML-136499, ML-136498, ML-136497, 1ER50D, 1ER50C, 1ER85C Troubleshooting, Alarms and Error Messages