Programming Guide (Cont.)

PARAMETER

 

STEPS

LEFT DISPLAY

RIGHT DISPLAY

 

Press

 

SELECT

OPTIONS

 

Press

 

ENGLISH (Factory Default)

LANGUAGE

Language

Press

to select a language.

ENGLISH/ESPANOL

 

 

 

 

 

 

FRANCAIS/DEUTSCH

 

 

 

 

HOLLAND

 

 

Press

when complete.

PROGRAM

 

 

 

 

 

 

 

Press

 

SELECT

OPTIONS

Melt Options

Press

 

NO MELT/LIQUID/SOLID

 

 

Press

to select melt options.

NO MELT/LIQUID/SOLID

 

 

 

(See Melt Options)

 

 

 

Press

when complete.

PROGRAM

 

 

 

 

 

 

 

Press

 

SELECT

OPTIONS

Recovery

Press

 

RECOVERY*

 

Time

Press

when complete.

PROGRAM

 

 

 

 

 

 

 

 

 

Press

 

SELECT OPTIONS

OPTIONS

 

Press

 

FILTER

PROG 0000

Filter

Press

to scroll through options.

FILTER

ACT 0000

 

 

Press

when complete.

PROGRAM

 

 

 

 

 

 

 

Press

 

SELECT

OPTIONS

Dispose

Press

 

DISPOSE

PROG 00

 

 

 

 

 

Press

to scroll through options.

DISPOSE

ACT00

 

Press

when complete.

PROGRAM

 

 

 

 

 

 

 

Press

 

SELECT

OPTIONS

Set Back

Press

Enter 11-99 min. of idle time

IDLE SET BACK

PROG 00

To

275°F

Press

when complete.

PROGRAM

PROG 00

 

 

 

 

 

 

*Recovery - During a cold start, the controller measures the time the fryer takes to heat from 200°F to 250°F (93°C to 121°C) and compares it with factory default values.

— 11 —

Page 11
Image 11
Vulcan-Hart ML-136496, ML-136499, ML-136498, ML-136497, 1ER50D, 1ER50C, 1ER85C, 1ER85D Recovery, Dispose, Set Back, 275F