INSTALLATION CODES AND STANDARDS

INSTALLATION CODES AND STANDARDS

Your Vulcan fryer must be installed in accordance with:

1.State and local codes.

2.The National Electrical Code, ANSI/NFPA No. 70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

3.NFPA Standard #96.

LEVELING

Place a carpenter's level on top of the fryer and level the fryer front-to-back and side-to-side by turning the adjustable legs. If your fryer is equipped with the optional non-adjustable casters, the fryer must be placed on a level surface.

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.

Place fryer as near to its final position as possible. Connect 3-phase line to X, Y and Z of terminal block. To reach terminal block, remove electric cover plate.

For each 151/2" section, a 3-phase supply line capable of handling 16 KW at the fryer's rated voltage (208, 240, 480) is required. A hood ventilator interlock should be connected to 1 and 2 on the 4-pole barrier strip. 1 and 2 go to a set of dry contacts on the power switch. (3/4 HP fan maximum, if needed.)

A wiring diagram is located inside the front door panel.