V SERIES HOLDING, TRANSPORT & PROOFING CABINET |
electrician. Do not remove the grounding prong from this plug.
Verify that the power source matches the Serial Data Plate located on the lower back corner of the cabinet and the plug configuration before the connection is made. (Fig.4)
(Fig. 4)
OPERATION
CONTROLS
The Cabinet and its parts are hot. Be very careful when operating, cleaning, or servicing the cabinet.
THERMOMETER | PROOF | THERMOSTAT |
| INDICATOR |
|
| LIGHT |
|
HOLD | PROOF / HOLD SWITCH | FAN |
INDICATOR |
| ON/OFF |
LIGHT |
| SWITCH |
Thermometer:
The Thermometer indicates the interior temperature of the cabinet.
Proof Indicator Light:
The Proof Indicator Light indicates power is supplied to the cabinet and the cabinet is in Proofing Mode.
Thermostat:
The Thermostat turns power on to the heating elements. If “Proofing mode” is desired, the thermostat should be set in the white “Proof” area (1 through 4.) If “Holding mode” is desired, the thermostat should be set in the red area (5 through 10.) (Fig. 5)
5
Hold Indicator Light:
The Hold Indicator Light indicates power is supplied to the cabinet and the cabinet is in Holding Mode.
Proof / Hold Switch:
Flip the switch upward for Proofing mode or flip the switch downward for Holding mode.
Fan On/Off Switch:
The Fan On/Off Switch turns the fan on or off only.
| Thermostat | Approximate | ||
Mode | Setting | Temperature | ||
PROOF | 1 | 100⁰F (37⁰C) | ||
2 | 110⁰F (43⁰C) | |||
| ||||
| 3 | 120⁰F (49⁰C) | ||
| 4 | 130⁰F (54⁰C) | ||
| 5 | 140⁰F (60⁰C) | ||
| 6 | 150⁰F (66⁰C) | ||
HOLD | 7 | 160⁰F (71⁰C) | ||
8 | 170⁰F (77⁰C) | |||
| 9 | 180⁰F (82⁰C) | ||
| 10 | 190⁰F | (88⁰C) | |
| (Fig.5) |
|
|