CLEAN UP

21.Lock gun, reduce pressure and turn Prime/Spray Knob to prime A .

22.Lay unit back on handle so inlet valve is facing upward. Clean threads of inlet valve with a damp cloth. Fill inlet valve with light household oil. See Figure 43. Slowly increase pressure to distribute the oil through the pump. Turn Prime/Spray Knob from

prime A to spray B to distribute oil. Replace large suction tube to inlet valve.

23.Turn Prime/Spray Knob to prime A , reduce pres- sure, shut sprayer off. Unplug sprayer. Refer to Pressure Relief.

24.Remove and clean suction set filter in clean water or solvent with soft brush. Reassemble.

Figure 43 - Fill Inlet Valve With Oil

IMPORTANT!

Proper cleaning and oiling of the pump after use are the most important steps you can take to insure proper operation after storage.

Figure 44 - Remove And Clean Filter

25.Wipe entire unit, hose and gun with a damp cloth to remove accumulated paint.

22

Page 22
Image 22
Wagner SprayTech 505 owner manual Fill Inlet Valve With Oil