IMPORTANT CLEANING
NOTES!
READ THESE NOTES AND
WARNINGS BEFORE YOU
START TO CLEAN YOUR
SPRAYER!
•When using latex paints, clean your sprayer and components using warm, soapy water.
When using
•Do not use mineral spirits on latex paint, or the mixture will turn into a
•No matter which cleaning solution you use, make sure to dispose of it properly when finished cleaning your sprayer.
•Thorough cleaning and lubrication of the sprayer is the most important step you can take to ensure proper operation after storage.
CALL 1-800-880-0993
IF YOU HAVE ANY QUESTIONS REGARDING THE CLEANUP OF YOUR SPRAYER
WARNING
Special cleanup instructions for use with flammable solvents:
•ALWAYS FLUSH SPRAY GUN AT LEAST ONE HOSE LENGTH AWAY FROM SPRAY PUMP.
•If collecting flushed solvents in one gallon metal container, place it into an empty five gallon container, then flush.
•Area must be free from vapors.
•Follow all cleanup instructions.
CLEANUP
PURGING THE PAINT HOSE
These steps will allow you to recover excess paint left over in the paint hose.
1.Lock the gun and remove spray tip assembly.
2.Submerge suction set into a bucket with appropriate cleaning solution.
3.Hold the spray gun against the side of the paint can and hold the trigger.
4.While holding the trigger, turn the pump ON (l), and turn the PRIME/SPRAY knob to SPRAY.
PRIME
l
SPRAY
Let the pump run until all paint is purged from the hose and cleaning solution is coming out of the gun.
5.Release the trigger.
6.Hold the spray gun against the side of a separate container and hold the trigger.
7.Trigger the gun until the fluid coming out of the gun is clear.
8.Turn the PRIME/SPRAY knob to PRIME and trigger gun once more to relieve pressure.
9.Move on to Cleaning the Suction
Set.
CLEANING THE SUCTION SET
1. | Lock the gun and turn |
| |
| the pump OFF (O). | o | |
2. | Remove the suction | ||
|
hose and return tube and clean it using the appropriate cleaning solution.
You should also wipe the threads of the inlet valve, and remove and clean the suction set screen.
3.When suction set is clean, thread the suction tube back onto the inlet valve, and replace the return tube onto the return tube fitting. Replace clip.
Return tube
fitting
Inlet valve
Clip
Return tube Suction set
4.Submerge the suction set into a bucket of NEW cleaning solution.
5.Turn the PRIME/SPRAY knob to PRIME, turn the pump to ON (l), and trigger the gun into a waste container to relieve the pressure.
PRIME | SPRAY |
l
6.Let the pump circulate the cleaning solution through the suction set for 2- 3 minutes.
7.Turn the pump OFF (O).
8.Move on to Cleaning the Spray Gun, next page.
English | Customer Service: | © 2003 Wagner Spray Tech - All rights reserved. |
|
|
|