OPERATING INSTRUCTIONS
START-UP AND REFILL PROCEDURES
Your Hot Spot® spa has been thoroughly tested during the manufacturing process to ensure reliability and
The following instructions must be read and followed exactly to ensure a successful
CAUTIONS
•Do not fill the spa with hot water, as tripping of the
•DO NOT CONNECT POWER TO AN EMPTY SPA. Power to the spa automatically activates critical components within the spa, such as controls, heater, and other systems. If power is supplied to these components prior to the spa being filled, the components will be damaged, and this may result in a
•Do not use your spa after filling until all of the steps listed below are completed.
•Do not add chlorine if treating your spa with polyhexamethylene biguanide (Biguanide, PHMB, eg. BaquaSpa®) sanitizer.
•Before filling your spa for the first time, remove the equipment compartment door and check to ensure that the unions on either side of the pump(s) and heater are
1.Ensure the drain is closed and remove the filter compartment cover, skimmer basket, weir, and filter. Then insert the end of a garden hose into the filter hole and begin filling the spa. The water level of your Hot Spot spa should be maintained at a level one inch above the highest jet in the spa. Reinstall the skimmer basket, weir, and filter once the spa is filled.
IMPORTANT: Watkins Manufacturing Corporation does not recommend that the spa be filled with “softened” water, as this may damage the spa’s equipment.
2.Install SPA FROG bromine and mineral cartridges. See Spa Frog Replacement Instruction section and install the cartridge.
IMPORTANT: Each time the spa is filled with water, you must remove and reinstall the SPA FROG cap, even if you are not replacing the cartridge, in order to properly prime the jet pumps.
3.AFTER the spa has been filled with water and the equipment compartment door is secured, power must be applied to the spa.
•115 volt models: Connect the GFCI to the waterproof receptacle and push the RESET button on the GFCI.
•230 volt models: Open the door of the electrical subpanel and reset the GFCI breaker. Close and secure the subpanel door.
4.The jet pump(s), heating system and all internal plumbing will achieve a partial prime as the spa is filled. To check the operation of the jet system and to purge any remaining air from the heating system, push the JETS button on the control pad twice (three times for Mallorca®) to make the jet pump(s) run on high speed for one minute. Once the jet system is fully operational (as indicated by strong,
5.Adjust Total Alkalinity (TA) to 125 ppm, Calcium Hardness (CH) to 150 ppm, then spa water pH to between 7.4 and 7.6. These procedures are listed in the “Water Quality and Maintenance” section.
IMPORTANT: Add spa water chemicals directly into the filter compartment after activating “Clean Cycle” (Press SET, then Jets button).
OPERATION NOTES:
1.Your spa is equipped with a
2.The spa controller has an automatic two hour
3.The spa controller also has a
Operating Instructions | Page 11 |
|
|