NOTE: Well water may contain high concentrations of minerals. The use of a low water volume,
Foam Inhibitors
Spa water requires changing due to the
Foam inhibitors, such as Hot Spring® FreshWater® Defoamer, can suppress foam, but cannot remove soap from the water. Soap is very difficult to remove from the water because soap is not oxidized by any chemical added to the spa. Only ozone can oxidize soap.
Eventually the soap
OZONE (OPTIONAL)
The FreshWater® III high output ozone system is the Watkins recommended ozone purification system for your spa. The FreshWater III ozone system utilizes Corona Discharge (CD) technology to produce a higher concentration of ozone than is produced by competing ultraviolet light (UV) ozone systems.
The FreshWater III high output ozone system greatly enhances the quality of the spa water when used to supplement the spa owner’s regular water maintenance program. Contrary to some information circulated throughout the pool and spa industry regarding ozone systems, ozone CAN NOT be used as a
Cleaning the Ozone Injector
On occasion, a mineral
1.Disconnect power to the spa.
2.Access the equipment compartment.
3.Locate the ozonator in the equipment compartment and unplug the ozonator from the control box.
4.Place 16 ounces (1/2 liter) of white vinegar into a container such as a cup or bucket. Place the container on the equipment compartment floor.
WARNING |
Nitric acid accumulates in the air lines of the ozonator and injector. Nitric acid will cause severe chemical burns if direct skin contact is made, so always wear protective gloves, glasses and clothing when working on the ozonator or injector lines. To prevent inhalation or ingestion of the nitric acid, DO NOT blow or inhale with your mouth to any of the adapters, fittings or tubing of the ozonator or injector air lines.
WARNING |
NOTE: White vinegar will not damage any of the spa components.
5.Carefully loosen the long Tygon / Kynar tubing to the bottom of the ozonator. A liquid substance may be found inside the tubing. If a liquid substance is present, BE CERTAIN NOT TO COME INTO CONTACT WITH THE LIQUID (SEE WARNING ABOVE).
6.Place the end of the tubing into the vinegar, making certain that the end of the tubing sits at the bottom of the container.
7.Reconnect power to the spa.
8.Run the spa until all 16 ounces (1/2 liter) of the vinegar are gone. This should allow an ample flow of vinegar to be run through the injector and clear the blockage.
9.Disconnect power to the spa.
10.Remove the empty cup or bucket.
11.Reinstall the tubing to the bottom of the ozonator.
12.Plug the ozonator into the control box.
13.Close the equipment compartment door.
14.Reconnect power to the spa.