SAFETY EQUIPMENT
A.GFCI: The Ground Fault Circuit Interrupter, located on the end of the power cord (115 Volt models only), is a safety device that is designed to sense as little as 5 milliamps of electrical current leakage to ground. It is very important to protect a GFCI from rain and other moisture. Watkins Manufacturing Corporation recommends that the GFCI be tested before each use to ensure it is functioning correctly.
To test the GFCI:
230 Volt, Permanently installed or converted Models: The GFCI breaker is located inside the subpanel, before each use of the spa and with the unit operating, push the Test button on each breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by switching it completely off and then completely on. The switch should then stay on.
B.HEATER
C.PRESSURE SWITCH: The pressure switch is located inside the control box on the heater, and is designed to prevent heater operation during
a no or low flow condition. If for any reason flow through the heater is reduced or stopped, the pressure switch will trip. If the pressure switch _ . _ . _ . _
has detected a no or low flow condition _ . _ . _ . _ will display. The most common causes of inadequate heater flow are a dirty or clogged
_ _ _ _
filter, obstruction in the plumbing lines, and
the pressure switch senses flow through the heater when the jet pump is not activated. Contact your Authorized Service Technician if displayed.
D.CONTROL THERMOSTAT: The control thermostat helps regulate the temperature of the water. If for any reason something were to happen to this device, the READY icon on the control panel will flash. Contact your Authorized Service Technician.
SPA CONTROL PANEL
Your control panel consists of an LED display and convenient touch pads that allow you to set the water temperature and adjust the skim/filter cycle settings, lock spa temp, lock entire spa functions, as well as control the hydrotherapy jets, and light from
LED DISPLAY
The LED display on your
SET BUTTON
Use the set button to control clean cycle, filter cycle, locking and light functions. To activate the desired mode, press the “SET” button. When the “SET” icon flashes push the applicable button. The “SET” mode ends after 3 seconds or when the “SET” icon stops flashing.
TEMPERATURE CONTROL
| Filter Cycle 1 |
| Temp / Lock |
|
|
| Icon | Set Icon | Display | Sleep |
|
| Jets Button |
| Temp | ||
Temperature Up |
| Icon | |||
|
| ||||
|
|
|
|
| Ready |
|
|
|
|
| Icon |
Temperature Down |
|
| Filter Cycle Icon |
Light Button | Set Button | Filter Cycle 2 | Light Icon |
Icon |
| ||
|
| Jet Icon |
|
The set temperature range is from 80°F (27°C) to 104°F (40°C). Temperatures of any setting may rise slightly depending on the current use and condition of your spa, and on outside temperature. Whenever power is disconnected and then reconnected to the
READYspa, the water temperature setting will automatically return to the last temperature entered into the program.
Pressing the Temp Up (▲) button displays the spa’s set temperature. To increase the set temperature, press the Temp Up (▲) button again, once for each degree of increased temperature desired. If you hold the button down, the set temperature will increase by one degree every half second.
Pressing the Temp down (▼) button displays the spa’s set temperature. To decrease the set temperature, press the Temp down (▼) button again, once for each degree of decreased temperature desired. If you hold the button down, the set temperature will decrease by one degree every half second.
JET PUMP CONTROL
Pressing the Jet button changes the jet pump functions, depending on the number of presses:
Operating Instructions | Page 13 |
|
|