Dynamics Sections Controls (top to bottom)

1.Compressor (white knobs)

a.The compressor’s Ratio/Slope can be set from 1 to infinity (limiter).

b.The Threshold is variably adjustable from +10 dB to -20 dB.

c.When the Attack time switch is set to Slow (F.ATK off,) attack time is auto- sensing and program dependent. In the Fast setting (F.ATK,) attack time will be forced to 1 ms.

d.Release time is adjustable from 0.1 sec to 4 seconds.

2.Expander/Gate (green knobs)

a.The expander’s Threshold is variable from -30 dB to +10 dB

b.Range is variable from 0 – 40 dB.

c.When the Attack time switch is set to Slow (F.ATK off,) attack time is auto- sensing and program dependent. In the Fast setting (F.ATK,) attack time is 1 ms.

d.Release time is adjustable from 0.1 sec to 4 seconds.

e.The GATE switch toggles the section from an expander (default mode) into a gate.

Page 5
Image 5
Waves SSL 4000 E, SSL 4000 G manual Dynamics Sections Controls top to bottom, Expander/Gate green knobs