Dynamics Sections Controls (top to bottom)
1.Compressor (white knobs)
a.The compressor’s Ratio/Slope can be set from 1 to infinity (limiter).
b.The Threshold is variably adjustable from +10 dB to
c.When the Attack time switch is set to Slow (F.ATK off,) attack time is auto- sensing and program dependent. In the Fast setting (F.ATK,) attack time will be forced to 1 ms.
d.Release time is adjustable from 0.1 sec to 4 seconds.
2.Expander/Gate (green knobs)
a.The expander’s Threshold is variable from
b.Range is variable from 0 – 40 dB.
c.When the Attack time switch is set to Slow (F.ATK off,) attack time is auto- sensing and program dependent. In the Fast setting (F.ATK,) attack time is 1 ms.
d.Release time is adjustable from 0.1 sec to 4 seconds.
e.The GATE switch toggles the section from an expander (default mode) into a gate.