Wayne 3014, 3514, 3018DLX user manual Adjustment # 3 Positive Mechanical Door Lock

Models: 3514 3014 3018 3018DLX

1 40
Download 40 pages 20.48 Kb
Page 28
Image 28
Adjustment # 3 Positive Mechanical Door Lock

Adjustment # 2 Contact Obstruction Sensing (Closing Direction)

The opener is designed to automatically reverse the door during closing travel whenever it comes in contact with an object up to the last 1 inch of travel above the floor. An object on the floor with a height less than 1” will cause the door to stop. (Test according to instructions on Step 27.)

If opener reverses properly with a 1” high solid test object laid flat on garage floor (Step 27) and stops without the solid test object in the fully closed position, proceed to Adjustment # 3.

When door comes in contact with a 1” high solid test object laid flat on garage floor and stops instead of reversing, reset the door close limits according to instruction in Step 27, adjusting until door reverses upon contact with the 1” high solid test object.

If door reverses when it comes in contact with the floor, reset the door close limits according to instruction in Step 27.

Adjustment # 3 Positive Mechanical Door Lock

The garage door opener is designed with an automatic mechanical locking system. This lock secures the door in the fully closed position.

To adjust, activate the door opener and allow the door to go to its fully closed position. Loosen the two screws on the rail stop and move it behind the chain latch assembly with a gap of 3/4” between “stop” and “latch”. Retighten screws.

28