Weber 56515 manual Gas Instructions, m WARNING If there is a leak at connection 1, 2, or

Models: 56515

1 64
Download 64 pages 63.14 Kb
Page 11
Image 11
mWARNING: If there is a leak at connection (1, 2, or 3),

GAS INSTRUCTIONS

Check:

A)Flexible Hose to bulkhead connection (1)..

B)Main gas line to bulkhead connection (2)..

C) Main gas line to manifold connections (3)..

mWARNING: If there is a leak at connection (1, 2, or 3),

retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after re-tightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

D)Flexible Hose to Quick Disconnect connection (4)..

E)Valves to manifold connections (5)..

m WARNING: If there is a leak at connections (4 or 5), turn

OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water..

Reinstall Control Panel

You will need: Phillips screwdriver..

F) Position top edge of control panel on tabs of frame.. Push down into position.. G) Reinstall igniter module..

H) Slide both shorter wind deflector tabs toward inside edge of control panel while you slide longer tab over outside edge.. Seek previous illustrations for reference..

I) Line up screws with screw holes on both control panel bracket and frame..

J)Tighten screws..

K)Place corresponding control knobs onto valve stems..

Manual backgroundManual backgroundManual backgroundManual background 2 1 Manual backgroundManual background

4

3 Manual background

The grill illustrated may have slight differences than the model purchased.

5

WWW.WEBER.COM® 11