 | OPERATING INSTRUCTIONS | 17 | |||
| MANUAL LIGHTING | 
 | 
 | 
 | 
 | |
| 1) | Remove rain shields. | 1. | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | |
| 
 | DANGER | 
 | 
 | 
 | 
 | 
| Failure to remove rain shields while igniting the | 
 | 
 | 
 | 
 | |
| fireplace’s burners, or not waiting 5 minutes to allow | 
 | 
 | 
 | 
 | |
| the gas to clear if the fireplace does not light, may | 
 | 
 | 4. | 6. | |
| result in an explosive  | 
 | 
 | |||
| 
 | 
 | 
 | 
 | ||
| serious bodily injury or death. | 
 | 
 | 
 | 
 | |
| 2) Make sure the burner control knob is turned OFF. (Push control knob | 2. | 5. | 
 | 
 | |
| 
 | 
 | 
 | 
 | ||
| 
 | down and turn clockwise to ensure that it is in the OFF position.) | 
 | 
 | 
 | 
 | 
| 3) Turn the gas supply valve on. | 
 | 
 | 
 | 
 | |
| 
 | WARNING: Do not lean over the open fireplace. Keep | 
 | 
 | 
 | 
 | 
| 
 | your face and body at least one foot away from the | 
 | 
 | 
 | 
 | 
| 
 | logs when lighting the fireplace. | 
 | 
 | 
 | 
 | 
| 4) Insert match holder with lit match near the center of the burner area. | 
 | 
 | 
 | 
 | |
| 5) Push in igniter several times, until burner is lit. | 
 | 
 | 
 | 
 | |
| 6) Check that the burner is lit. | 
 | 
 | 
 | 
 | |
| 
 | WARNING: If the burner does not light, turn the | 
 | 
 | 
 | 
 | 
| 
 | burner control knob to OFF and wait 5 minutes to let | 
 | 
 | 
 | 
 | 
| 
 | the gas clear before you try again or try to light with a | 
 | 
 | 
 | 
 | 
| 
 | match. | 
 | 
 | 
 | 3. | 
| 
 | 
 | 
 | 
 | 
 | |
| Note: Normal burning pattern will develop light soot on log set. If heavy | 
 | 
 | 
 | 
 | |
| 
 | sooting occurs, refer to troubleshooting. | 
 | 
 | 
 | 
 | 
TO EXTINGUISH
Push in the burner control knob and turn clockwise to the OFF posi- tion. Turn gas supply OFF at the source. When unit has cooled, replace rain shields.