| 18 | TROUBLESHOOTING | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | PROBLEM | 
 | CHECK | CURE | 
 | 
| 
 | Burner burns with a dark orange | 
 | Inspect Spider / Insect Screen for pos- | Clean Spider / Insect Screen. (See Section | |
| 
 | flame, in conjunction with heavy soot- | sible obstructions. (Blockage of holes.) | “Annual Maintenance”) | ||
| 
 | ing. | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | |
| 
 | Burner does not light, or flame is low | Is fuel hose bent or kinked? | Straighten fuel hose. | ||
| 
 | in HIGH position. | 
 | 
 | 
 | 
 | 
| 
 | 
 | Is igniter functioning properly? | Replace igniter (see contact info. below). | ||
| 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | Is the igniter box blocked? | Remove obstructions from igniter box (see | |
| 
 | 
 | 
 | 
 | pg. 10, Step 11 of “Assembly” Section). | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | Burner flame pattern is erratic. Flame | Are burner holes blocked? | Clean burner holes. (See Maintenance Sec- | ||
| 
 | is low when burner is on HIGH. Flames | 
 | tion.) | ||
| 
 | do not ignite all burner holes. | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.