TECHNICAL DATA
SPECIFICATIONS
Fuel | No. 2 Fuel Oil |
|
|
BF3 Firing rate - Effective Output | 0.50 to 0.95 US GPH - 70,000 to 133,000 BTU/h |
|
|
BF5 Firing rate - Effective Output | 0.75 to 1.65 US GPH - 105,000 to 231,000 BTU/h |
|
|
Voltage (single phase) | 120V 60Hz (+ 10% - 15%) |
|
|
BF3 Absorbed electrical power | 192 Watts |
|
|
BF5 Absorbed electrical power | 204 Watts |
|
|
Motor (rated) | 3250 rpm Run Current 2.2 AMP |
|
|
Capacitor | 12.5 Microfarads 260V |
|
|
Pump pressure | 100 to 200 PSI |
|
|
Primary control | RIELLO 530 SE/C |
|
|
Ignition transformer | 8kV 16mA |
|
|
BURNER AND MOUNTING FLANGE DIMENSIONS
Model |
| A | B | C | D | E |
| F | |
|
|
|
|
|
|
|
|
|
|
BF3 | Inches | 9 | 13/16 | 11 1/4 | 7 1/2 | 3 1/2 | 4 5/8 | 8 | 21/32 |
mm |
| 249 | 286 | 193 | 89 | 117 |
| 220 | |
|
|
| |||||||
BF5 | Inches | 9 | 13/16 | 11 1/2 | 7 1/2 | 3 1/2 | 6 5/16 | 6 | 13/16 |
mm |
| 249 | 292 | 193 | 89 | 160 |
| 173 | |
|
|
|
BURNER COMPONENTS IDENTIFICATION
1
17 |
| 7 |
|
| |
2 |
| 6 |
|
| |
3 |
|
|
4 |
| 5 |
|
| |
| D8174 |
|
8 | 9 | 10 |
| 11 |
3 | 0 |
| 12 |
15 | 16 |
14 | 13 |
3398
GB
B
A
E F
D
C
D7515
| ° |
|
|
|
0 |
|
|
| |
6 |
|
| ° |
|
|
| 5 |
| |
|
| 4 |
| ° |
|
|
| 0 | |
|
|
| 3 |
|
” | mm |
9 | |
16 |
|
/ | 90 |
3 |
5
7 9/16” - 192 mm
8 | 1/ ” - 216 mm |
|
| 2 | D7516 |
|
|
BURNER COMPONENTS
1Lockout indicator lamp and reset button
2Primary control
3Primary control
4Pump pressure regulator
5Post purge timer
6Air adjustment
7Capacitor
8Combustion head
9Mounting gasket
10Universal mounting flange
11Turbolator adjustment screw
12Coil
13Bleeder and pressure gauge port
14Return fuel line port
15Inlet fuel line port
16Pump
17Air pressure switch
2