GB

PUMP PURGE

 

NOTE: To protect the pump gears, it is advisable to lubricate the

B

pump prior to purging a lift system.

C

Apply oil through the VACUUM PORT (C).

 

A) SINGLE LINE (GRAVITY FEED SYSTEM)

 

I. Loosen the bleeder valve (A) until oil flows out.

A

Tighten the bleeder valve securely and startburner.

 

II. When bleeding the pump by pressure:

 

1) Loosen the bleeder valve (A).

 

2)Disconnect nozzle oil supply line at the pump nozzleport (B).

3)Attach a flexible plastic tube to the pump nozzle, port directing the oil flow into a bucket.

4)Loosen the screw(s) securing the air tube cover, allowing it to be removed freely.

5)Holding the air tube cover in its proper location start the burner.

6) When the solenoid valve is engaged approximately 10 seconds after starting, remove the air tube cover and shine a light source on the photocell, allowing it to see false light.

D7527

7) Run the burner until the fuel pump has been purged of air, then tighten the bleeder valve and immediately shut down the burner.

8) Reinstall the air tube cover and nozzle line.

9) The burner can now be started normally.

WARNING: Omitting steps 2 and 3 will result in a collection of unburned oil in the combustion chamber creating a hazardous situation upon burner startup.

B) TWO LINE (LIFT SYSTEM)

Turn off the main power source to the burner and remove the air tube cover. Shines a light source on the photocell (now visible where the air tube cover was removed), return power to the burner and activate the burner. With the light source in place, the burner will operate in prepurge only. Once the burner is purged, turn off the power source and replace the air tube cover. Return power to the burner. The burner is now ready to operate.

ATTENTION: It is important that the fuel line be completely sealed and free from air leaks or any internal blockages.

WARNING! WHEN THE BYPASS PLUG IS INSTALLED, A TWO-PIPE SYSTEM MUST BE USED OR FAILURE OF THE PUMP SHAFT WILL OCCUR.

SETTING THE AIR ADJUSTMENT PLATE

A) The initial air damper setting is made by turning screw (2) until the top edge of the air damper (3) is aligned with the number ac- cording to the burner setup chart.

B) Further adjustments can be made with the burner cover in place by removing plastic plug on the top right hand side of the cover. Turn the screw counter clockwise (+ indicator) to increase com- bustion air, turn the screw clockwise (- indicator) to decrease combustion air.

C) The final position of the air damper will vary on each installation. Use instruments to establish the proper settings for maximum CO2 and a smoke reading of zero.

NOTE:

Variations in flue gas, smoke, CO2, and temperature readings may be experienced when the burner cover is put in place.

Therefore, the burner cover must be in place when making the final combustion instrument readings, to ensure proper test results.

2

1

3

D5141

3398

8

Page 11
Image 11
Weil-McLain 800061000-Brn-PO Rie BF5 manual Pump Purge, Setting the AIR Adjustment Plate, TWO Line Lift System

800061000-Brn-PO Rie BF5, 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5 specifications

The Weil-McLain 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5, and 800061000-Brn-PO Rie BF5 are part of the manufacturer’s premier line of residential and commercial heating solutions. Renowned for their durability, efficiency, and advanced engineering, these models are designed to meet the diverse heating demands of modern buildings.

One of the standout features of the Weil-McLain Rie BF5 series is their robust construction. These boilers are typically built with high-grade cast iron, which not only enhances their longevity but also ensures superior heat retention. This design allows the boilers to operate efficiently over extended periods, minimizing the need for repairs and replacements.

Efficiency is a critical factor in today’s heating systems, and the Weil-McLain BF5 series excels in this category. With energy-efficient ratings, they are designed to reduce energy consumption while maintaining optimal performance. This leads to lower utility bills for homeowners and businesses alike, contributing to overall cost savings.

The technology integrated into the Rie BF5 series also plays a pivotal role in their operation. Advanced combustion technology ensures clean, efficient burning of fuel. This results in lower emissions, making these units a more environmentally friendly choice. Additionally, the incorporation of modulating gas valves allows for precise control of the heating output, enhancing comfort levels while reducing energy wastage.

Another notable characteristic is the versatility of the BF5 series. They come in various output capacities, making them suitable for a wide range of heating applications, from small residential spaces to larger commercial environments. The compact design also facilitates easier installation, making it simpler for contractors to integrate them into existing systems.

Moreover, the Weil-McLain Rie BF5 series is equipped with user-friendly controls that provide homeowners and facility managers with the ability to monitor and adjust settings as needed. This feature not only enhances user convenience but also contributes to overall performance optimization.

In conclusion, the Weil-McLain 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5, and 800061000-Brn-PO Rie BF5 embody advanced heating technology, exceptional efficiency, and durable construction. These characteristics make them an excellent choice for those seeking reliable heating solutions that stand the test of time while being environmentally conscious. Whether for residential or commercial use, these boilers deliver consistent performance and comfort, making them a trusted option in the industry.