COMBUSTION CHAMBER PRESSURE CHART

RIELLO BURNER SET UP SHEET GB Manual background

COMBUSTION CHAMBER PRESSURE CHART

 

 

 

 

BURNER OUTPUT VS CHAMBER PRESSURE CHART

 

CHAMBERPRESSURE (INCHESWC)

0.5

 

 

 

 

 

 

 

0.1

 

 

 

 

 

 

 

 

0.4

 

 

 

 

 

 

 

 

0.3

 

 

 

 

 

 

 

 

0.2

 

 

 

 

 

 

 

D7525

0.0

0.50

0.75

1.00

1.25

1.50

1.75

(GPH) BURNER OUTPUT

RIELLO BURNER SET UP SHEET

Weil McLain Part No.

8000-60000

8000-61000

8000-62000

 

 

 

 

Riello Part No.

C8512352

C8512353

C8512354

Burner Model

Riello 40

BF5

BF5 Factory

BF5 Factory

BF5 Factory

Series

preset *1

preset *1

preset *1

 

 

Boiler

UO3

UO3

UO4

UO5

Input

GPH

0,8

1,0

1,2

1,4

Nozzle

Delavan

.65 X 70°B

.85 X 60°B

1.00 X 70°B

1.10 X 70°B

Pump Pressure

PSI

150

145

145

160

 

 

 

 

 

 

Turbolator

Setting

0

1

3

4

Air Gate Setting

3.5

4.25

5.0

5.5

Air tube length

inches

8

8

8

8

Ait tube insertion

inches

4 1/4"

4 1/4"

4 1/4"

4 1/4"

 

 

 

 

 

 

*1 Nozzle pre-installed at factory.