BCP-3 Output Modes Wiring
BCP-3
| SYSTEM | = |
|
|
| 147F |
| |||
| TARGET | = |
|
|
| 150F |
| |||
|
| Boiler |
| SYS | 2 | DHW |
| |||
| Output 1 | OutputPump | OutputPump 3 |
| ||||||
|
|
| SET |
|
|
|
| |||
|
|
|
| T3+ T3- EXT+ |
| P+ P- COM 24VAC |
| |||
|
|
|
|
|
| |||||
| T1 COM T2 COM | EXT- |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
System Sensor | Outdoor Sensor | DHW Call | Enable Dry Contact | Setback Timer | |
|
|
|
|
| |
SYSTEM | = |
|
| 147F | |
TARGET | = |
|
| 150F | |
Boiler | SYS |
|
| DHW | |
Pump |
|
| Pump | ||
Output 1 | Output 2 | Output 3 | |||
| SET |
|
|
| |
T1 COM | T2 COM | T3+ T3- EXT+ | EXT- | P+ | P- COM 24VAC |
System Sensor | Outdoor Sensor | DHW Call | Enable Dry Contact | Setback Timer |
|
|
| L | 120 VAC |
|
|
| ||
|
|
| N |
|
Power (Black) |
|
|
| |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output capped
(White/Output 3) | |
Boiler |
|
(Blue/ |
|
Output 2B) |
|
L | 120 VAC |
N |
|
System Pump (Yellow/Output 1)
Wiring 1 On/Off Boiler +
System Pump
| L | 120 VAC | ||
| N | |||
Power (Black) | ||||
|
|
| ||
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
Boiler2 |
(White/ |
Output 3) |
Boiler1 |
(Blue/ |
Output 2) |
L 120 VAC |
N |
System Pump (Yellow/Output 1)
Wiring 2 On/Off Boilers +
System Pump
|
|
|
|
|
| L 120 VAC | |||
SYSTEM | = |
|
| 147F |
| Power (Black) |
| N | |
TARGET | = |
|
| 150F |
|
|
| ||
|
|
|
|
|
| ||||
Boiler |
| SYS | 2 | DHW |
|
|
| 3) | |
Output 1 | OutputPump | OutputPump 3 |
|
|
| ||||
SET |
|
|
|
|
|
|
| Pump (White/Output | |
T1 COM T2 COM T3+ | T3- EXT+ EXT- | P+ P- | COM | 24VAC |
|
| |||
|
|
|
|
|
|
| Boiler |
| DHW |
|
|
|
|
|
|
| (Blue/ |
| |
|
|
|
|
|
|
| output 2) |
| L 120 VAC |
|
|
|
|
|
|
|
|
| |
Sensor |
|
|
|
| Timer |
|
|
| N |
|
|
|
|
| System Pump |
|
| ||
|
|
|
|
| (Yellow/Output 1) |
| |||
System Outdoor Sensor |
| DHW Call | Enable Dry Contact | Setback |
| Wiring 1 On/Off Boiler + | |||
|
| System Pump + DHW Pump | |||||||
|
|
|
|
| |||||
|
|
|
|
| L | 120 VAC | |||
SYSTEM | = |
|
| 147F |
| Power (Black) | N |
| |
TARGET | = |
|
| 150F |
|
|
|
|
SYS DHW
Boiler Pump Pump
Output 1 Output 2 Output 3
| SET |
|
|
|
|
T1 COM T2 | COM T3+ | T3- EXT+ EXT- P+ P- | COM 24VAC |
|
|
|
|
|
| Boiler Lo | Boiler Hi |
|
|
|
| (Blue/ | (White/ |
|
|
|
| Output 2) Output 3) | |
SensorSystem SensorOutdoor | CallDHW ContactDryEnable | TimerSetback | L | 120 VAC | |
N |
| ||||
|
|
|
|
| |
|
|
|
| System Pump |
|
|
|
|
| (Yellow/Output 1) |
|
|
|
|
| Wiring 1 Lo/Hi Boiler + | |
|
|
|
| System Pump |
SYSTEM | = | 147F |
TARGET | = | 150F |
Boiler | SYS | DHW |
Pump | Pump | |
Output 1 | Output 2 | Output 3 |
SET |
|
T1 COM | T2 COM T3+ T3- EXT+ EXT- | P+ P- COM 24VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| System Sensor |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Setback Timer |
| |||
|
|
|
|
|
|
| ||||
Outdoor Sensor |
|
|
|
|
| |||||
|
|
| Enable Dry Contact |
| ||||||
|
|
|
| |||||||
|
|
|
| DHW Call |
|
|
|
| L | 120 VAC | ||
| N | |||
Power (Black) | ||||
|
|
| ||
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
Boiler 3 (White/ Output 3)
Boiler 2
(Blue/
Output 2)
Boiler 1 (Yellow/ Output 1)
Wiring 3 On/Off Boilers
NOTES:
•The
•Weil McLain recommends not sharing the power source to the control with any pumps, boilers, or heavy electric equipment.
•When wiring a sensor to the
•Eventhough in some Output Modes the
6