General Specifications
Table 2 – Burner Specifications
Capacity | LB & LC |
| Firing rate 0.40 – 1.35 GPH |
| Input 56,000 – 189,000 Btu |
|
|
| LD & LF |
| Firing rate 1.10 - 1.75 GPH |
| Input 154,000 – 245,000 Btu/h |
Fuels | U. S No. 1 or No. 2 heating oil only |
| ...........(ASTM D396) |
| Canada No. 1 stove oil or No. 2 |
| .........furnace oil only |
Electrical | Power supply 120 volts AC, 60 Hz, |
| .............single phase |
| Operating load 5.8 Amps max |
| Motor 1/7 hp, 3450 rpm, NEMA 48M |
| frame PSC rotation CCW |
| when facing shaft end |
| Ignition Continuous duty |
| igniter |
Fuel pump | Outlet pressure ...... Note 1 |
Air tube | ATC code .......See Table 3 |
|
|
Dimen- | Height (maximum) |
sions | Width (maximum) 15 inches |
(with | Depth ............ |
cover) | Air tube diameter |
Note 1. See appliance manufacturer’s burner specifica- tions for recommended outlet pressure.
General Specifications
!Warning–Professional
Service Required
This equipment must be installed, adjusted and put into operation only by a qualified individual or service agency that is:
x Licensed or certified to install and provide technical service to oil heating systems.
x Experienced with all applicable codes, standards and ordinances
x Responsible for the correct installation and commission of this equipment
x Skilled in the adjustment of oil burners using combustion test instruments.
The installation must strictly comply with all applicable codes, authorities having jurisdiction and the latest revision of the National Fire Protection Association Standard for the Installation of
Regulation by these authorities take precedence over the general instructions provided in this installation manual.
Read and understand the manual supplied with this equipment. Incorrect installation, adjustment, and use of
this burner may result in severe personal injury death, or substantial property damage from fire, carbon monoxide poisoning, soot or explosion.
S105
Table 3 – Air Tube Combination (ATC) codes
Firing rate | Head | ATC codes for usable air tube | ||
(gph) |
|
| lengths: |
|
| 5” | 7” | 9” | |
NX50LB | NX70LB | NX90LB | ||
NX50LC | NX70LC | NX90LC | ||
NX50LD | NX70LD | NX90LD | ||
NX50LF | NX70LF | NX90LF |
•Certifications/approvals
Underwriters Laboratories has certified this burner to comply with ANSI/UL 296 and has listed it for use with #1 or #2 fuel oil as specified in ASTM D396. Low sulfur #1 and #2 fuel oils reduce heat exchanger deposits with all burners compared to the standard fuels. Reduced deposits extend the service interval for cleaning and improve the effi- ciency of the appliance over time. Low sulfur fuels reduce particulate and oxides of nitrogen emis- sions as well. The Oilheat Manufacturers’ Associa- tion recommends these fuels as the preferred fuels for this burner.