Hazard Definitions
! CAUTION

Hazard Definitions

 

 

 

Indicates a hazardous situ-

! DANGER

 

ation, which, if not avoided,

 

will result in death or serious injury.

 

Indicates a hazardous

! WARNING

 

situation, which, if not

 

avoided, could result in death or serious injury.

Indicates a hazardous situation, which, if not

avoided, could result in minor or moderate injury.

Within the boundaries of the hazard warning, there will be information presented describing consequences if the warning is not heeded and instructions on how to avoid the hazard.

NOTICE Intended to bring special attention to information, but not related to personal injury or property damage.

General Information

!WARNING Owner’s Responsibility

Incorrect installation, adjustment, and use of this burner could result in severe personal injury, death, or sub- stantial property damage from fire,

carbon monoxide poisoning, soot or explosion.

Contact a professional, qualified service agency for the installation, adjustment and service of your oil heating system. This work requires technical training, trade ex- perience, licensing or certification in some states and the proper use of special combustion test instruments.

Please carefully read and comply with the following instructions:

yNever store or use gasoline or other flammable liquids or vapors near this burner or appliance.

yNever attempt to burn garbage or refuse in this appliance.

yNever attempt to light the burner/appliance by throwing burning material into the appliance.

yNever attempt to burn any fuel not specified and approved for use in this burner.

yNever restrict the air inlet openings to the burner or the combustion air ventilation openings in the room.

NOTICE This manual contains information that applies to both AF and AFG burners. These burners may appear to be basically identical, but there are differences in design and performance. Please review the comparison chart below:

Feature

AF

AFG

Static Pressure Capability

Conventional - Low range

Enhanced - Medium range

Blower Wheel Design

Standard strip

Special tablock

 

 

 

Inlet Airflow Design

Standard inlet bell

Special airguide

UL Air Tube Combinations

“F” Series ONLY

“F” or “M” Series

Igniter Gaskets Baseplate/Barrier

Optional, as specified

Required, always specified

Low Firing Rate Baffle

Not required

Required, per specification

Figure 1. Burner label location

6104BAFG R06