General Specifications
Table 2 – Air Tube Combination (ATC) codes
Firing | Head | Static | Ven- |
|
|
| ATC Codes for usable air tube lengths |
|
|
| |||
Rate |
| plate | turi |
|
|
|
| (‘A’ in inches; See Figure 3.) |
|
|
| ||
(gph) |
| size |
|
|
|
|
|
|
|
|
|
|
|
(min- |
| (inches) |
| 5 | 7 | 9 | 13 | 16 | |||||
max) |
|
|
|
|
|
|
|
|
|
|
|
|
|
F0 | None | AF44XR | - | AF53XR | AF65XR | - | AF72XR | AF90XR | AF104XR | AF130XR | A160XR | ||
F3 | None | AF44XN | - | AF53XN | AF65XN | - | AF72XN | AF90XN | AF104XN | AF130XN | AF160XN | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F4 | None | AF44WH | - | AF53WH | AF65WH | - | AF72WH | AF90WH | AF104WH | AF130WH | AF160WH | ||
F6 | None | AF44YB | - | AF53YB | AF65YB | - | AF72YB | AF90YB | AF104YB | AF130YB | AF160YB | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F12 | None | AF44XO | - | AF53XO | AF65XO | - | AF72XO | AF90XO | AF104XO | AF130XO | AF160XO | ||
F22 | None | AF44XP | - | AF53XP | AF56XP | - | AF72XP | AF90XP | AF104XP | AF130XP | AF160XP | ||
F31 | None | None | AF44XS | - | AF53XS | AF65XS | - | AF72XS | AF90XS | AF104XS | AF130XS | AF160XS | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L1 | 8hole | - | AFG50MB | - | - | AFG70MB | - | AFG90MB | - | - | - | ||
L2 | 8hole |
| AFG50MP | - | - | AFG70MP | - | AFG90MP | - | - | - | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
V1 | 8hole | - | AFG50MD | - | - | AFG70MD | - | AFG90MD | - | - | - | ||
F0 | None | AF44WG | - | AF53WG | AF65WG | - | AF72WG | AF90WG | AF104WG | AF130WG | A160WG | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Notice Special Requirements
yTHE INSTALLATION OF A BURNER SHALL BE IN ACCORDANCE WITH THE REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
yFor recommended installation practices in the U.S. refer to the latest edition of NFPA 31. (CSA- B139 and
yConcealed damage — If you discover damage to the burner or controls during unpacking, notify the carrier at once and file the appropriate claim.
yWhen contacting Beckett for service information
—Please record the burner serial number (and have available when calling or writing). You will find the serial number on the silver label located on the left rear of the burner. Refer to Figure 1.
!WARNING ProfessionalRequired Service
Incorrect installation, adjustment, and use of this burner could result in severe personal injury, death, or
substantial property damage from fire, carbon monoxide poisoning, soot or explo- sion.
Please read and understand the manual supplied with this equipment. This equipment must be installed, ad- justed and put into operation only by a qualified individu- al or service agency that is:
yLicensed or certified to install and provide tech- nical service to oil heating systems.
yExperienced with all applicable codes, standards and ordinances.
yResponsible for the correct installation and com- mission of this equipment.
ySkilled in the adjustment of oil burners using combustion test instruments.
The installation must strictly comply with all applicable codes, authorities having jurisdiction and the latest revi- sion of the National Fire Protection Association Standard for the installation of
Regulation by these authorities take precedence over the general instructions provided in this installation
6104BAFG R06 | Page 5 |