Wells B446, B506, B406 operation manual Electrcal Hook-Up

Models: B446 B406 B506

1 24
Download 24 pages 39.56 Kb
Page 8
Image 8
ELECTRCAL HOOK-UP

ELECTRCAL HOOK-UP

Refer to the nameplate. Verify the electrical service power. Voltage and phase must match the nameplate specifications. Connecting the griddle to the wrong voltage can severely damage the unit or cause noticeable decreased performance.

Use copper wire suitable for a minimum of 90°C for electrical supply connections.

Broilers are factory wired three-phase (3ø). For single-phase (1ø) wiring, refer to the wiring diagram attached to the broiler. Conversion to 1ø must be performed by a licensed electrician.

This broiler is not fused. Protect the circuit with properly sized fuses or circuit breaker.

An electrical disconnect must be installed readily accessible to the operator of the broiler.

162 303673 OpManual for Built-In Electric Charbroilers

6

Page 8
Image 8
Wells B446, B506, B406 operation manual Electrcal Hook-Up