INSTALLATION (continued)

INSTALLATION (continued)

4.For Cook ‘N Hold warmers:

a.Verify that provided sealants are applied to the underside of the warmer top flange prior to setting the unit into the cutout.

b.After installation, verify that the tabs on the Wellsloks are turned out to lock the warmer into the counter

c.Apply a thin bead of food-grade silicone sealant around the flange to seal it to the counter.

d.Wellslok extension kits are available for installing warmers in counter tops where the standard Wellslok would not normally reach. The extension kit will adapt to counter tops up to 1¾” thick.

ELECTRICAL INSTALLATION

1.Refer to the product nameplate. Verify the electrical service power. Voltage and phase must match the nameplate specifications. Wiring the warmer to the wrong voltage can severely damage the unit or cause noticeably decreased performance.

2.Available electrical service amperage must meet or exceed the specifications listed on the specification sheet provided with the warmer.

3.Warmer and control unit must be connected to an appropriate building ground. Ground connection will be marked “GND” or ” ELECTRICAL INSTALLATION " .

NOTE: Wire gauge, insulation type and temperature rating , as well as type, size and construction of conduit, must meet or exceed applicable specifications of local codes and of the National Electrical Code.

E. PLUMBING INSTALLATION

1.IMPORTANT: All plumbing installations must be performed by a qualified plumber.

2.For units equipped with a DRAIN LINE: Some jurisdictions may require an approved air gap or other back-flow prevention device in the drain. It is the responsibility of the plumber to determine such requirement, to provide and properly install the required device.

NOTE: Damage caused by leaks due to improper installation is NOT covered by warranty.

CAUTION:

ELECTRIC

SHOCK HAZARD

The ground lug of this appliance must be connected to a suitable building ground.

IMPORTANT:

Contact a licensed electrician to install and connect electrical power to the appliance.

IMPORTANT: Damage due to being connected to the wrong voltage or phase is NOT covered by warranty.

IMPORTANT: Electrical installation other than as specified on the specification sheet will void the UL listing, and may void the warranty.

NOTE: Plumb connections must be made in compliance with all Federal, State and Local Plumbing Codes and Ordinances.