112 Installing System Components
a
Grasp the expansion card by its edges, bend outward on both card-
edge guides, and carefully remove the card from the expansion-card
connector.
b
With the blue card-edge guides still bent outwards, lift the side of the
controller that is adjacent to the blue guide, and then remove the
controller towards the front of the chassis.
Installing the Integrated Storage Controller Card
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
1
Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
2
Open the system. See "Opening the System."
3
Install the controller card in the expansion slot on riser 1 labeled
INT_STORAGE.
a
Holding the card by its edges, with the card-edge facing the riser,
insert one side of the card into the black card-edge guide. Bend
outward on the blue card-edge guide, lower the card onto the blue
card-edge guide, and release the guide. See Figure3-17.
b
Insert the card-edge connector firmly into the expansion-card
connector until the card is fully seated and the plastic card guides fit
over the edges of the card.
4
Connect the card to the SAS backplane:
a
Connect the SAS data cable connector labelled "SAS_0" to the white
SAS_0 connector on the card, and the connector labelled "SAS_1" to
the black SAS_1 connector on the card. See Figure3-17.
NOTE: Be sure to connect the cable according to the connector labels on the
cable. The cable will not function properly if reversed.
b
Route the SAS data cable through the channel on the inner side of the
chassis.