ELECTRICAL COMPONENTS INSTALLATION INSTRUCTIONS

ELECTRICAL COMPONENTS INSTALLATION INSTRUCTIONS

A. HI-LIMIT THERMOSTAT

1. Install THERMOWELL in lower threaded hole in frypot. Use hi-temperature pipe thread compound.

2. Insert HI-LIMIT THERMOSTAT thermobulb

into THERMOWELL. DO NOTuse any type

of pipe thread compound or tape. Thread the compression fitting into THERMOWELL and tighten finger-tightonly.

NOTE: The thermobulb sits in the thermowell, and not directly in the hot oil. Thus it is not necessary to over-tighten the compression fitting.

Wrench tightening this fitting will make it impossible to remove should service be required at a later date.

3.Attach body of HI-LIMIT THERMOSTAT to the left mounting bracket below the control panel and connect wiring.

B.TEMPERATURE CONTROL THERMOCOUPLE

9/16“SLOTTED

DEEPWELL SOCKET

1.Install THERMOCOUPLE in upper threaded hole in frypot. Use hi-temperature pipe thread compound.

2.Tighten using a slotted 9/16" deepwell socket or offset flare nut wrench, taking care to not damage the thermocouple leads.

3.Connect thermocouple leads to controller terminals 2 (white or +) and 3 (red or -).