ELECTRICAL COMPONENTS INSTALLATION INSTRUCTIONS
A. HI-LIMIT THERMOSTAT
1. Install THERMOWELL in lower threaded hole in frypot. Use
2. Insert
into THERMOWELL. DO NOTuse any type
of pipe thread compound or tape. Thread the compression fitting into THERMOWELL and tighten
NOTE: The thermobulb sits in the thermowell, and not directly in the hot oil. Thus it is not necessary to
Wrench tightening this fitting will make it impossible to remove should service be required at a later date.
3.Attach body of
B.TEMPERATURE CONTROL THERMOCOUPLE
9/16“SLOTTED
DEEPWELL SOCKET
1.Install THERMOCOUPLE in upper threaded hole in frypot. Use
2.Tighten using a slotted 9/16" deepwell socket or offset flare nut wrench, taking care to not damage the thermocouple leads.
3.Connect thermocouple leads to controller terminals 2 (white or +) and 3 (red or
19