B.ELECTRICAL INSTALLATION

B.ELECTRICAL INSTALLATION

1.The fryer is equipped with a three-prong grounding plug (NEMA 15-5P) for your protection against shock hazard. The fryer must be plugged directly into a properly grounded three-prong receptacle (NEMA 15-5R).

CAUTION - ELECTRICAL SHOCK HAZARD

DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.

Ungrounded electrical equipment cause personal injury

and property damage.

GROUND

PRONG

NEMA 5-15P

NEMA 5-15R

PLUG

RECEPTACLE

2.The installation of this fryer must conform to local codes. In the absence of local codes, the installation of this fryer must conform with the National Electrical Code (ANSI Z223.1).

In Canada, CSA C22.2 is applicable.

3.DO NOT obstruct the flow of the two exhaust flues (item 14) at the top rear of the fryer. It is especially critical that gas supply piping and electrical supply cord and/or receptacle be routed away from the path of the hot combustion fumes.

4.Because the fryer draws less than 8 amps, two fryers may be plugged into the same 15 amp circuit if required.