Western Digital WDE2170, WDE4360 Temperature and Humidity, Cooling, Component Location Maximum

Models: WDE4360 WDE2170

1 54
Download 54 pages 29.69 Kb
Page 24
Image 24

SpecificationsWD Enterprise WDE2170/WDE4360

2.5.2. Temperature and Humidity

Table 2-11. Temperature and Humidity

 

 

Temperature and Humidity

 

 

 

Operating1

 

Temperature

5°C to 55°C (41°F to 131°F)

Humidity

10-90% RH non-condensing

 

33°C (maximum wet bulb)

Thermal Gradient

10°C/hour (maximum)

Non-Operating

 

Temperature

-40°C to 60°C (-40°F to 140°F)

Humidity

5-95% RH non-condensing

 

33°C (maximum wet bulb)

Thermal Gradient

20°C/hour (maximum)

 

 

1The system environment must provide sufficient air flow to limit maximum surface temperatures as defined in Table 2-12.

2.5.3. Cooling

Drive component temperatures must remain within the limits specified in Table 2-12. Figure 2-7 and Figure 2-8 show the temperature measurement locations. Sustained operation at temperatures in excess of the reliability values degrades the MTBF rating. Short excursions up to, but not exceeding, the maximum values do not affect the MTBF rating. Maximum component temperature ratings must not be exceeded under any operating condition. The drive may require forced air cooling to meet specified operating temperatures.

Table 2-12. Maximum & Reliability Operating Temperature Limits

Component

Location

Maximum

 

 

 

Drive Baseplate

#1, Figure 2-7.

65°C (149°F)

 

 

 

4915

#2, Figure 2-8.

95°C (203°F)

 

 

 

64C96

#3, Figure 2-8.

80°C (176°F)

 

 

 

2298

#4, Figure 2-8.

80°C (176°F)

 

 

 

1501

#5, Figure 2-8.

85°C (185°F)

 

 

 

Reliability1

55°C (131°F)

80°C (176°F)

65°C (149°F)

65°C (149°F)

70°C (158°F)

1Sustained operation at temperatures in excess of the reliability values degrades the MTBF rating.

16

RELEASED 04-08-97

4079-001045 Rev. B

Page 24
Image 24
Western Digital WDE2170, WDE4360 manual Temperature and Humidity, Cooling, Component Location Maximum, Reliability1