SpecificationsWD Enterprise WDE2170/WDE4360
2.5.2. Temperature and Humidity
Table | |
|
|
Temperature and Humidity |
|
|
|
Operating1 |
|
Temperature | 5°C to 55°C (41°F to 131°F) |
Humidity | |
| 33°C (maximum wet bulb) |
Thermal Gradient | 10°C/hour (maximum) |
|
|
Temperature | |
Humidity | |
| 33°C (maximum wet bulb) |
Thermal Gradient | 20°C/hour (maximum) |
|
|
1The system environment must provide sufficient air flow to limit maximum surface temperatures as defined in Table
2.5.3. Cooling
Drive component temperatures must remain within the limits specified in Table
Table
Component | Location | Maximum |
|
|
|
Drive Baseplate | #1, Figure | 65°C (149°F) |
|
|
|
4915 | #2, Figure | 95°C (203°F) |
|
|
|
64C96 | #3, Figure | 80°C (176°F) |
|
|
|
2298 | #4, Figure | 80°C (176°F) |
|
|
|
1501 | #5, Figure | 85°C (185°F) |
|
|
|
Reliability1
55°C (131°F)
80°C (176°F)
65°C (149°F)
65°C (149°F)
70°C (158°F)
1Sustained operation at temperatures in excess of the reliability values degrades the MTBF rating.
16 | RELEASED |