Connect to drain (observe local codes)
1.The unit is provided with a gravity drain.
2.The ideal installation has a standpipe
3.It may be desirable to insulate drain line thoroughly up to drain inlet.
Connect drain pump
If a drain connection directly below the drain tube outlet is not available, install a drain pump in the rear compartment of the ice maker. The drain pump must meet these specifications:
l
l
It must be
Overall maximum outside dimensions: 15” (381 mm) wide x 6” (152 mm) deep x
l
l
Minimum pump flow rate: 24 gallons
(91 liters) per hour [0.4 gallons (1.5 liters) per minute] at 12 feet (3.7 m) lift.
Operating temperature range: 55°F (13°C) to 110°F (44°C).
5