Begin the installation

Begin the installation

Remove racks and all other contents from oven before moving appliance. Be sure to remove all packaging material (cardboard, protective film, etc.) from range before use.

A. Remove shipping skid

.m..CARDBOARDPADS UNDER APPLIANCE

SHIPPING iKID \

,.

Remove the 4 cardboard pads from shipping box. Place them on floor as shown to protect appliance’s finish. Rest appliance (on its back) on pads.

Remove the two 318” shipping bolts from wooden skid. Discard the skid.

B. Extend leveling legs

ADJUSTABLE WRENCH

BOTTOM OF

LEVELING LEG

Once skid is removed, 4 leveling legs are exposed at bottom of frame.

Loosen legs by applying an adjustable wrench to the 1%” base of the leveling legs. Back each of them out about 4 complete turns.

Stand appliance on its base.

Begin electrical connection

Grounding Instructions

WARNING:

THIS APPLIANCE MUST BE CONNECTED TO A GROUNDED, METALLIC, PERMANENT WIRING SYSTEM, OR AN EQUIPMENT GROUNDING CON- DUCTOR SHOULD BE RUN WITH THE CIRCUIT CONDUCTORS AND CONNECTED TO THE EQUIP- MENT GROUNDING TERMINAL OR LEAD ON THE APPLIANCE.

CAUTION: Before connecting flexible armored cable for permanent wiring, disconnect power at fuse box or circuit breaker.

A. Remove terminal block cover

3/8” BRASS NUTS 3

TERMINAL

BLOCK ,

COVER

Terminal block cover is located on back of the ap- pliance near the bottom.

Remove retaining screws to expose electrical terminal block.

USE ONLY the supplied 3/8” brass nuts when connec- ting cord.

USE ONLY ring type terminals to connect cord.