B. Strain relief required

B. Strain relief required

LOCKING

,

II

INSERT FROM

UNDER FRAME

Disconnect clamping ring from strain relief. Push relief (from bottom) through hole beneath terminal block. Tighten clamping ring (from above) onto strain relief

threads.,_.~.,,--.L-n-U -I--Y.-w- W-m _--,.- is*~l--T-i+..4

RUN CORD THROUGH

STRAIN RELIEF

Run cord or cable through strain relief.

Leave enough slack to attach ring-type terminals to terminal block. Tighten clamping screws.

C. If frame grounding is allowed

SILVER COLORED

NEUTliAIv

1 ’ ’

Use this wiring method ONLY if local codes permit connecting frame grounding conductor to neutral wire of power cord.

THIS APPLIANCE IS MANUFACTURED WITH

NEUTRAL TERMINAL CONNECTED TO THE FRAME.

If local codes do not permit grounding through the neutral. The 3-conductor cord or cable assembly must be replaced by a 4-conductor cord. The replacement cord must be rated 240 volts, 50 amperes and investigated for use with ranges.

1.Connect neutral wire to the center silver-colored terminal.

2.Connect remaining 2 wires to the terminals on either side of the silver colored terminal.

3.Use ring type terminals only. Connect with the brass nuts that are taped to the frame. Do not loosen fac- tory installed nuts already on the terminal.

4.Replace terminal block cover.

D. 4-wire electrical connections

SILVER COLORED.

TERMINAL

i

y

I”’

RELIEF

:

Use this wiring method for mobile homes and whenever a 4-wire installation is required.

1.Remove the grounding strap screw from the range frame. Keep this ground screw. Bend up the ground- ing strap so that it does not contact the range frame.

2.Connect the green ground wire to the frame of the appliance with the ground screw, using the hole in the frame where the ground strap was removed.

3.Connect the white neutral wire of the power cord to the silver colored terminal of the terminal block. Con- nect the remaining wires to the outer terminals.

4.Replace the terminal block cover.