Optional exhaust installations

This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.

WARNING

Fire Hazard

Cover unused exhaust holes with one of the following kits:

279818 (white)

279925 (biscuit)

279969 (pewter)

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the “Assistance or Service” section of this manual to order.

Over the top Installation: Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch

Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch

Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

ABC

A. Standard rear offset exhaust installation B. Left or right side exhaust installation

C. Bottom exhaust installation (Not an option with pedestal installations.)

Determine Vent Length

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90º turns when possible.

better good

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown.

Refer to the manufacturer’s instructions.

2. Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

AB

A. Over the top installation (also available with one offset elbow)

B. Periscope installation

10

Page 10
Image 10
Whirlpool 8562594 Optional exhaust installations, Special provisions for mobile home installations, Determine Vent Length