Electrical Requirements For Your Air Conditioner
ELECTRICAL REQUIREMENTS ARE DIFFERENT FOR THE TWO MODELS SHOWN ON THE COVER, DEPENDING ON THE AMPERE RATING OF YOUR UNIT. THE NUMBER OF AMPERES IS PRINTED ON THE SERIAL PLATE, ATTACHED TO THE FRONT OF THE UNIT, BEHIND THE FRONT PANEL (SEE PAGE 2).
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES
Do not, under any circumstances, remove the power supply cord ground prong.
RECEPTACLE WIRING
RECEPTACLE WIRING should be at least as large as 14 gauge. Use copper wire only. It is the
personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri-
cian. OBSERVE NATIONAL ELECTRICAL
CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES.
Electrical Requirements
A 115 volt (103.5 min., 126.5 max.) 60 hertz AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay circuit breaker re- quired). It is recommended that a separate circuit, serving only this appliance, be provided for models with serial plate amperes up through 7.5. A separate circuit is required for models with serial plate amperes of 7.6 through 72.0. Do not use an extension cord.
grounding type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded
Figure 1
WALL RECEPl ‘ACLE
ALTERNATE GROUNDING METHOD
If changing and properly grounding the wall receptacle is impossible and where local codes permit (consult your electrical inspector), a temporary adapter may be plugged into the existing
HOWEVER, IS NOT RECOMMENDED.
If this is done, you must connect the grounded eyelet on the adapter to the wall receptacle cover plate screw and from this same screw, you must connect a separate copper ground wire (#14 minimum) to a grounded cold water pipe.* See Figure 2. Do not ground to a gas supply pipe. Do not connect to electrical supply until appliance is permanently grounded.
GROUND ASSEMBLY (ATTACH TO GROUNDED
ELECTRICALLY GROUNDED MET COLD WATER PI (REMOVE PAINT
Electrical Connection
Electrical Ground is Required on this Appliance
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a
RECEPTACLE
POWER SUPPLY CORD
*Cold water pipe must have metal continuity to
electrical ground and not be interrupted by plastic, rubber or other electrically insulating connectors (including water meter or pump) without adding a jumper wire at these con- nections.