Requirements

Requirements

Requerimientos

Electrical requirements

Requerimientos

eléctricos

WARNING

ADVERTENCIA

 

 

 

 

 

Peligro de Choque Eléctrico

Electrical Shock Hazard

 

 

Conecte a un contacto de pared de conexión a tierra

Plug into a grounded 3 prong outlet.

 

 

de 3 terminales.

Do not remove ground prong.

 

 

No quite el terminal de conexión a tierra.

Do not use an adapter.

 

 

No use un adaptador.

Do not use an extension cord.

 

 

No use un cable eléctrico de extensión.

Failure to follow these instructions can result in death,

 

 

No seguir estas instrucciones puede ocasionar la

fire, or electrical shock.

 

 

muerte, incendio o choque eléctrico.

 

 

 

 

 

 

 

 

A

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Check with a qualified electrician if you are not sure the air conditioner is properly grounded.

A three-wire, single-phase, 60-Hz, AC-only, electrical supply is required on a separate circuit. A 15-amp time-delay fuse or circuit breaker is required. Copper wire (#14 gauge) is required.

The model and serial label (A) is located behind the front panel.

Si los códigos lo permiten y se utiliza un alambre de puesta a tierra separado, se recomienda que un electricista calificado determine si la trayectoria de la puesta a tierra es adecuada.

Consulte con un electricista calificado para asegurarse de que el acondicionador de aire está debidamente puesto a tierra.

Se requiere un suministro eléctrico monofásico de tres alambres, de 60 Hz, sólo de CA, en un circuito separado. Se requiere un fusible de retardo de 15 amperes o un disyuntor. Use solamente alambre de cobre (calibre #14).

La etiqueta de modelo y serie (A) se encuentra detrás del panel delantero.

Recommended ground method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating, 3-prong ground-type outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded, 3-prong outlet installed by a licensed installer.

It is the customer’s responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, and all local codes and ordinances.

Copies of the standards listed may be obtained from:

*National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269

Specific electrical requirements are listed in the chart.

Power supply cord plug

Wiring requirements

outlet

 

 

• 115 volt (103.5 min. -

 

126.5 max.)

 

0-12 amperes

 

15-amp time-delay fuse or

 

circuit breaker

 

• 14 gauge copper wiring

Método recomendado para la puesta a tierra

Para su seguridad personal, este acondicionador de aire debe ser puesto a tierra. Este acondicionador de aire está equipado con un cordón eléctrico provisto de un enchufe con clavija tripolar de conexión a tierra. Para reducir a un mínimo el riesgo posible de un choque eléctrico, el cordón debe enchufarse en un tomacorriente mural para clavija con 3 terminales que coincidan con los polos de la clavija, puesto a tierra de acuerdo con todos los códigos y reglamentos

locales. Si no se dispone de un tomacorriente para clavija tripolar, es responsabilidad del cliente hacer instalar un tomacorriente para clavija con tres terminales debidamente puesto a tierra por un electricista con licencia.

Es responsabilidad del cliente:

Llamar a un instalador eléctrico calificado.

Asegurarse de que la instalación eléctrica sea adecuada y esté hecha de acuerdo con el Código Nacional de Energía, ANSI/NFPA 70, última edición*, y todos los códigos y reglamentos locales.

Pueden obtenerse copias de las normas señaladas del:

*National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269

Los requerimientos eléctricos específicos se indican en la tabla.

Tomacorriente para la

Requisitos de cableado

clavija del cordón eléctrico

 

 

• 115 voltios (103,5 mín. -

 

126,5 máx.)

 

0-12 amperes

 

• Fusible de retardo de

 

15 amperes o disyuntor

 

• Alambre de cobre calibre #14