3.insert finish frame into wail opening. Square and level the frame. Nail frame securely to the wall studs.

4.Remove the ground wire and screw from the front of the unit base. Save grounding screw for reattachment in Step 13.

5.Slide unit out of cabinet. Grasp handle and slide unit straight out of cabinet. Place unit on cardboard to protect your floor covering.

6.insert cabinet into the wail opening. The top of the cabinet should extend W (13 mm) into the room. If there is trim, the cabinet should extend W’ (13 mm) past the trim.

7.Check the outward slope of the cabi- net. Place a carpenter’s level inside the cabinet on the right side. There should be l/2 bubble (%” [6 mm] per foot [30.5 cm]) slope toward the outside. Also check the left side.

NOTE: Make sure the air conditioner cabinet has the proper outward slope so condensate water runs to the outside or damage could result to the floor or wall.

8.Seal opening between cabinet and finish frame. Use the insulation removed in Step 1.

9.Attach cabinet to finish frame. Use #lO x 1” (25 mm) wood screws (not supplied) to attach cabinet to the frame.

IMPORTANT: Do not over-tighten screws or the cabinet will distort and provide a poor air seal between the cabinet and the air conditioner.