Whirlpool ACS052XH1 warranty voltmodels with amperes from 7.6 through, Outlet wiring

Models: ACS052XH1

1 24
Download 24 pages 22.88 Kb
Page 7
Image 7
115-volt models with amperes from 7.6 through 12.0

E L E C T R I C A L R E Q U I R E M E N T S

115-volt models with amperes from 7.6 through 12.0

Outlet wiring

Outlet wiring should be a minimum of

14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.

Electrical requirements

A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15-ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air condi- tioner, be provided.

Electrical connection

Electrical ground is required on this air conditioner.

Recommended ground method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical Code (ANSI/NFPA 70 – latest edition) and local codes and ordinances. If a mating outlet is not available, it is the responsibility of the customer to have a properly grounded 3-prong outlet installed by a qualified electrician.

3-prong ground plug

Ground prong

Power supply cord

3-prong ground-type outlet (single outlet)

7

Page 7
Image 7
Whirlpool ACS052XH1 voltmodels with amperes from 7.6 through, E L E C T R I C A L R E Q U I R E M E N T S, Outlet wiring