Whirlpool GZ5730XR Make Electrical Connection, Direct Wiring Installation, Rectangular vent only

Models: GZ5736XR GZ5730XR

1 24
Download 24 pages 33.13 Kb
Page 8
Image 8
Rectangular vent only:

9.Remove either top or rear rectangular knockout. If using 7" (17.8 cm) round vent, remove both top rectangular knockout and the semi-circular knockout.

A

Round vent only: B

C

A. Semi-circular knockout

B. Top rectangular knockout

C. Rear rectangular knockout

10.Install damper:

AMake Electrical Connection

Direct Wiring InstallationManual background C

B

C

Vertical vent

B

Horizontal vent

position

 

position

A. Up to 1” (2.5 cm) side-to-side adjustment

B.Pivot

C.Damper/vent connector

Rectangular vent only:

Attach damper/vent connector over knockout opening. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap.

NOTE: For horizontal vent systems, it is recommended that the rectangular ventwork be attached to the damper/vent connector and sealed with duct tape before installing the hood.

Round vent only:

Replace round vent plate removed in step 1 of “Prepare the Hood” section.

Install a 7" (17.8 cm) round damper (must be purchased separately). The damper flap must open freely in the direction of air flow (away from range hood).

NOTE: Damper/vent connector and round vent plate can be installed up to 1" (2.5 cm) on either side of hood center if ventwork is off-center. In extreme off-center installations, one end of the vent connector may need to be trimmed to clear the electrical strain relief.

Make Electrical Connection

Direct Wiring Installation

Manual backgroundWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Manual backgroundWARNING

Electrical Shock Hazard

Electrically ground the blower.

Connect ground wire to green ground screw in wiring box.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.If not previously done, run wiring through wall or cabinets according to electrical codes and ordinances.

3.Stand hood up as shown. (Keep on protective cover to protect hood and cooking surface.) Feed the power supply cable through the strain relief.

4.Use twist-on connectors and connect black wires together.

5.Use twist-on connectors and connect white wires together.

8

Page 8
Image 8
Whirlpool GZ5730XR Make Electrical Connection, Direct Wiring Installation, Rectangular vent only, Round vent only