INPUT/OUTPUT VOLTAGES (LCD Washer)
Description | Connector/ | Connector/ | Voltage | Comments |
| Pin Number | Pin Number |
|
|
Bleach water valve output | P1(5) | P8(2) | 120 VAC |
|
|
|
|
|
|
Chassis Ground | P3(1) |
| Ground |
|
|
|
|
|
|
Cold water valve output | P1(4) | P8(2) | 120 VAC | |
|
|
|
|
|
Door Lock output | P1(1) | P8(2) | 120 VAC | 60 millisecond pulse |
|
|
|
|
|
Door lock switch input | P2(3) | P3(8) | 24 VDC |
|
|
|
|
|
|
Door switch input | P8(1) | P8(2) | 120 VAC |
|
|
|
|
|
|
Door unlock output | P8(3) | P8(2) | 120 VAC | 60 millisecond pulse |
|
|
|
|
|
Drain pump output | P6(4) | P8(2) | 120 VAC |
|
|
|
|
|
|
Heater - Neutral | P6(1) | P8(1) | 120 VAC | MAH7500 Only (~14 ohms) |
|
|
|
|
|
High water level - input | P1(8) | P8(2) | 120 VAC |
|
|
|
|
|
|
Hot water valve output | P1(3) | P8(2) | 120 VAC | 500 - 1K ohms |
|
|
|
|
|
L1 to machine control board | P6(2) | P8(2) | 120 VAC |
|
|
|
|
|
|
L1 to motor control | P6(3) | P8(2) | 120 VAC |
|
|
|
|
|
|
Lower water level - input | P2(3) | P3(5) | 24 VDC |
|
|
|
|
|
|
Motor control tach | P2(1) | P2(3) | 24 VDC |
|
|
|
|
|
|
Neutral (120 VAC) | P8(2) |
| Neutral |
|
|
|
|
|
|
Unbalance input | P2(3) | P3(4) | 24 VDC |
|
|
|
|
|
|
Softener water valve | P1(6) | P8(2) | 120 VAC |
|
|
|
|
|
|
Sump thermistor | P5(3) | P5(4) | VDC | NTC device (see thermistor |
|
|
|
| temperature chart - page |
|
|
|
| model only |
Torque PWM | P2(2) | P2(3) | 24 VDC |
|
|
|
|
|
|
Water valve thermistor | P3(6) | P3(7) | 5 VDC | |
|
|
|
|
|
INPUT/OUTPUT VOLTAGES (LED Washer)
Description | Connector/ | Connector/ | Voltage | Comments |
| Pin Number | Pin Number |
|
|
Bleach water valve output | P1(5) | P8(2) | 120 VAC |
|
|
|
|
|
|
Chassis Ground | P3(1) |
| Ground |
|
|
|
|
|
|
Cold water valve output | P1(4) | P8(2) | 120 VAC | |
|
|
|
|
|
Door Lock output | P1(1) | P8(2) | 120 VAC | 60 millisecond pulse |
|
|
|
|
|
Door lock switch input | P2(3) | P3(8) | 24 VDC |
|
|
|
|
|
|
Door switch input | P8(1) | P8(2) | 120 VAC |
|
|
|
|
|
|
Door unlock output | P8(2) | P8(2) | 120 VAC | 60 millisecond pulse |
|
|
|
|
|
Drain pump output | P8(4) | P8(2) | 120 VAC |
|
|
|
|
|
|
(Open) | P6(2) | P8(1) |
|
|
|
|
|
|
|
High water level - input | P1(8) | P8(2) | 120 VAC |
|
|
|
|
|
|
Hot water valve output | P1(3) | P8(2) | 120 VAC | 500 - 1K ohms |
|
|
|
|
|
L1- machine control board | P6(1) | P8(2) | 120 VAC |
|
|
|
|
|
|
L1- motor control | P8(3) | P8(2) | 120 VAC |
|
|
|
|
|
|
Lower water level - input | P2(3) | P3(5) | 24 VDC |
|
|
|
|
|
|
Motor control tach | P2(1) | P2(3) | 24 VDC |
|
|
|
|
|
|
Neutral (120 VAC) | P6(3) |
| Neutral |
|
|
|
|
|
|
Unbalance input | P2(3) | P3(4) | 24 VDC |
|
|
|
|
|
|
Softener water valve | P1(6) | P8(2) | 120 VAC |
|
|
|
|
|
|
Torque PWM | P2(2) | P2(3) | 24 VDC |
|
|
|
|
|
|
Water valve thermistor | P3(6) | P3(7) | 5 VDC | |
|
|
|
|
|
16010486