The following rules determine the maximum number of redistribution attempts that will be allowed in each spin step before the machine control skips the step and continues with the spin profile (See Section 2: Unbalance Con- trol System).
Push-To-Start Relay Operation
STARTING THE WASHER
1.With the door closed, press the
2.The red no. 28 wire sends a signal to the machine control to start running.
3.120 VAC is supplied to the machine con- trol board through black wire no. 27.
4.The machine control closes an internal switch to energize the line relay.
5.When the
STOPPING THE WASHER
1.With the washer running, power is supplied to the machine control and washer from gray wire no. 26 through the line relay.
2.When the user presses the
3.The machine control opens the internal logic switch which
4.When the user releases the
MACHINE CONTROL BOARD
INTERNAL LOGIC
SWITCH
120 VAC LINE (When door is
closed)
| 120 VAC POWER |
LINE | FROM MACHINE |
CONTROL BOARD | |
RELAY |
|
NO | C OM |
GY 26 | BK 27 |
120 VAC Line
To Timer &
Motor Control Board
RD 28
PUSH TO START SWITCH