Before you start...
Proper installation is your responsibility, Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate can be found on the underside of the cooktop burner box. Write down your
Note: This cookfop is manufactured for use with Natural gas. To convert for use with L.F?/Propane gas requires Kit No. 4173631, available from your Whirlpool dealer or authorized parts distributor.
Product Dimensions
Burner box helght -
30” mln. base cabinet is required. If cabinet has a drawer, a 3” depth clearance from \ the countertop to the top of the drawer (or other obstruction) in base cabinet is required.
This cooktop is not approved for use with downdruft vent systems.
Check location where
ALL OPENINGS IN THEWALL OR FLOOR WHERETHECOOKTOP ISTO BE INSTALLEDMUSTBESEALED.
Grounded electrical outlet is required. See “Electrical requirements.”
Proper gas supply connection must be available. See “Gassupply requirements.”
Countertop opening dimensions that are shown must be used. Given dimensions provide required 0” clearance.
Important: Observe all governing codes and ordinances. Failure to meet codes and ordinances could lead to fire or electrical shock.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
- Do Not store or use gasoline or | ||
other flammable | vapors and | |
liquids in the vicinity of this or | ||
any other | appliance. | |
- WHATTO DO IFYOU SMELL GAS | ||
l Do Not try to light any | ||
appliance. |
| |
l Do Not touch any electrical | ||
switch; Do Not use any phone | ||
in your building. | ||
l Immediately call your gas | ||
supplier | from | a neighbor’s |
phone. Follow | the gas | |
supplier’s | instructions. | |
l If you cannot reach your gas |
Cabinet and Cutout | Dimensions |
|
| ||
|
|
| 30” | mln |
|
| p- |
| :E:::k:p | - |
|
1” min. | space |
|
|
|
|
between | adjacent |
| distance |
|
|
cookiops | Minimum | 13” max. | Y | ||
| to | nearest | rear | ||
|
| ||||
| combustible surface | cabinet | \ | ||
| above cooktop | depth | |||
|
|
|
supplier, call the fire |
department. |
- Installation and service must be |
performed by a qualified installer, |
service agency or the gas |
Isupplier. |
Fire Hazard
\I |
| \ | |
| mln. | ||
| space | to | front |
| edge | of | c&net |
Wall aas line /
I
Do Not obstruct the flow of combustion and ventilation air.
Injury Hazard
To eliminate the risk of burns or fire, avoid installing cabinet storage above the cooking surface. If cabinets are already installed, reduce the hazard of reaching over a heated cooking surface by installing a range hood. The range hood should extend a minimum of 5 inches out
Important: Observe all governing codes and ordinances.
Failure to meet codes and ordinances could lead to fire or electric shock.
5” below count&on |
|
|
| |
and centered | In |
|
|
|
cabinet. | I | Centerline | 01 | I I |
|
| |||
| ! /wall | and | unlt |
|
Do Not pinch the power supply cord between the cooktop and cabinet.
from the bottom front of the cabinets.
Reaching over a heated cooking surface could result in a serious burn or other injury.
Clearance | Dimensions |
|
|
|
|
|
|
|
|
|
|
| l ** Note: 30” mln. when bottom 01 | ||||
|
|
|
| wood or metal cabinet Is | l/4” | |||
|
| I | I | Drotected | bv not | less than | ||
|
|
|
| ilome retard’ant mlllboard | . | |||
|
|
|
| covered wlth not less than No. | ||||
|
|
|
| 28 MSG sheet steel, 0.0 15” |
| |||
| See | Note*** |
| stalnless | steel, 0.024” alumlnum | |||
|
| or | 0.020” | copper. |
|
| ||
| for | mlnlmum |
| 38’ | mln. clearance | between the | ||
| clearances. |
| ||||||
|
| top of the cooklng plattorm and | ||||||
|
|
|
|
the bottom of an unprotected wood or metal sheet.
| nearest | combustible |
\ | surface | above cookfop |
Electrical Shock Hazard IIt is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that electrical installation is iadequate and in conformance with IUational Electrical Code ANSUNFPA 70 - Iatest edition* and all local codes and cordinances.
1rake special care when drilling holes into t he wall for electrical wiring. Electrical unrires may be concealed behind the wall c:overing.
F‘ailure to do so could result in death or zserious iniurv.
Copies of the standards listed may be obtained from:
‘National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
‘*American Gas Association 1515 Wilson Boulevard Arlington, Virginia 22209
Panel A