Check Operation

1.Check that you:

did not skip any steps.

installed all parts.

properly installed dryer legs.

leveled dryer.

have secured all exhaust vent joints with 100 mm (4") clamps.

have all the tools you started with.

2.Plug power supply cord into earthed outlet or connect direct wire to power supply. Turn power supply on.

3.Read the Use and Care Guide to fully understand your new dryer. Select a full heat cycle (not the air cycle) and start dryer. After five minutes, open dryer door. You should feel heat inside dryer.

If the burner did not ignite and you do not feel heat inside the dryer, shut the dryer off for 5 minutes, then check the following:

electrical supply is connected.

house fuse is intact and tight; or circuit breaker has not tripped.

dryer door is closed.

controls are set in a running or “On” position.

start button has been pushed firmly.

If dryer makes an unusual noise, check that the dryer is level.

Technical Specification

Moving dryer to a new location?

Check with a qualified electrician to confirm that supply voltage at new home matches voltage specified on the model/serial rating plate.

Remove power cord plug from power supply.

 

Tape top

 

to cabinet.

 

Tape

Have a qualified

door to

gas technician

front

shut off and

panel.

disconnect the

 

gas supply to

 

the dryer.

 

 

Turn

 

leveling

 

legs all the

 

way in.

Slide dryer onto cardboard or hardboard before moving it across the floor to prevent damaging floor covering.

220-240V~50Hz 1ph 3A max. IPX4 Clothes capacity: 9.1 kg max.

Factory set for NATURAL GAS:

Injector size: 2.2 mm Heat input gross: 5.9 kW

 

 

 

 

European Country:

 

GB, ES, PT

GR, IT

 

 

 

 

European Gas Category:

 

II2H3+

II2H3B/P

Gas Flow Rate:

 

0.562703 m3/hr

0.562703 m3/hr

Supply pressure (G20):

 

20 mbar

20 mbar

 

 

 

 

Factory adjusted pressure:

 

7.4 mbar

7.4 mbar

 

 

 

With LPG conversion kit: Injector size: 1.25 mm Heat input

gross: 5.7 kW

 

 

 

 

European Country:

 

GB, ES, PT

GR, IT

 

 

 

 

European Gas Category:

 

II2H3+

II2H3B/P

Butane supply pressure (G30):

 

28-30 mbar

30 mbar

 

 

 

 

Adjusted pressure:

 

N/A

N/A

 

 

 

 

Propane supply pressure (G31):

 

37 mbar

30 mbar

 

 

 

 

Adjusted pressure:

 

N/A

N/A

NOTE: Conversion kit : From Natural Gas to LP Gas : Whirlpool Part No. 279918.

Manufacturer : Whirlpool Corporation, Benton Harbor, Michigan 49022, USA.

11