11
1. Check that you:
did not skip any steps.
installed all parts.
properly installed dryer legs.
leveled dryer.
have secured all exhaust vent joints with 100 mm (4")
clamps.
have all the tools you started with.
2. Plug power supply cord into earthed outlet or connect direct
wire to power supply. Turn power supply on.
3. Read the Use and Care Guide to fully understand your new
dryer. Select a full heat cycle (not the air cycle) and start
dryer. After five minutes, open dryer door. You should feel
heat inside dryer.
If the burner did not ignite and you do not feel heat inside the
dryer, shut the dryer off for 5 minutes, then check the following:
electrical supply is connected.
house fuse is intact and tight; or circuit breaker has not
tripped.
dryer door is closed.
controls are set in a running or “On” position.
start button has been pushed firmly.
If dryer makes an unusual noise, check that the dryer is level.
Check Operation
Technical Specification
Moving dryer to a new location?
Check with a qualified electrician to confirm that supply voltage
at new home matches voltage specified on the model/serial
rating plate.
Remove power
cord plug from
power supply.
Have a qualified
gas technician
shut off and
disconnect the
gas supply to
the dryer.
Tape top
to cabinet.
Tape
door to
front
panel.
Turn
leveling
legs all the
way in.
Slide dryer onto cardboard or hardboard
before moving it across the floor to
prevent damaging floor covering.
220-240V~50Hz 1ph 3A max.IPX4 Clothes capacity: 9.1 kg max.
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross:5.9 kW
European Country: GB, ES, PT GR, IT
European Gas Category: II2H3+ II2H3B/P
Gas Flow Rate: 0.562703 m3/hr 0.562703 m3/hr
Supply pressure (G20): 20 mbar 20 mbar
Factory adjusted pressure: 7.4 mbar 7.4 mbar
With LPG conversion kit: Injector size:1.25 mm Heat input gross: 5.7 kW
European Country: GB, ES, PT GR, IT
European Gas Category: II2H3+ II2H3B/P
Butane supply pressure (G30): 28-30 mbar 30 mbar
Adjusted pressure: N/A N/A
Propane supply pressure (G31): 37 mbar 30 mbar
Adjusted pressure: N/A N/A
NOTE:Conversion kit : From Natural Gas to LP Gas :Whirlpool Part No. 279918.
Manufacturer :Whirlpool Corporation, Benton Harbor, Michigan 49022, USA.