Whirlpool W10173324B Natural Gas Conversion, To Convert Gas Pressure Regulator

Models: W10173324B

1 32
Download 32 pages 28.21 Kb
Page 15
Image 15
Natural Gas Conversion

Natural Gas Conversion

Manual backgroundWARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

NOTE: Gas conversions (from natural gas to LP gas or from LP gas to natural gas) must be done by a qualified person.

Manual backgroundWARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

To Convert Gas Pressure Regulator

1.Ensure that the manual shutoff valve is in the closed position.

A

C

B

A. Shutoff valve in openposition

A. Shutoff valve in “open” position

B. Gas supply line

C. To range

2.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A. Shutoff valve in “open” position

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

3.Remove the cap from the gas pressure regulator using a flat blade screwdriver.

4.Reinstall the cap and tighten with the flat blade screwdriver.

Manual backgroundA

A. Brass cap

5.Turn the cap over so that N or NAT is visible.

Manual backgroundA

A. Brass cap

6.Reinstall the cap.

15

Page 15
Image 15
Whirlpool W10173324B installation instructions Natural Gas Conversion, To Convert Gas Pressure Regulator