Make Gas Connection

Make Gas Connection

Typical rigid pipe connectionWARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Typical rigid pipe connection

A combination of pipe fittings must be used to connect the range to the existing gas line. Your connection may be different; according to the supply line type, size, and location.

1.Apply pipe joint compound made for use with LP gas to all pipe thread connections.

2.Using a pipe wrench to tighten, connect the gas supply to the range.

 

B

 

C

A

 

 

D

 

E

 

F

 

G

A. Pressure regulator

D. Union

connection fitting

E. Nipple

B. 90˚ elbow

F. Manual shutoff valve

C. Black iron pipe

G. ¹⁄₂" to ³⁄₄" gas pipe

Typical flexible connection

1.Use a combination wrench to attach the flexible connector to the adapters. Check that connector is not kinked.

A

 

B

 

 

 

D

 

C

 

 

E

F

 

 

G

 

H

 

A. Pressure regulator

E. Adapter

 

connection fitting

F. Use pipe joint compound

B. Use pipe joint compound

G. Manual shutoff valve

C. Adapter

H. ¹⁄₂" to ³⁄₄" gas pipe

D. Flexible connector

 

 

Complete Connection

1.Locate gas pressure regulator in the broiler.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

2.Check that the gas pressure regulator shutoff valve is in the “ON” position.

Gas Pressure Regulator

 

 

B

Front View

 

Side View

 

 

 

A

C

 

 

 

 

A. Shutoff valve

B.Front

C.“ON” position

3.Open the manual shutoff valve in the gas supply line. The valve is “open” when the handle is parallel to the gas pipe.

A

B

A. Closed valve

 

 

B. Open valve

4.Test all connections by brushing on the approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

5.Close the broiler door.

6.Place burners, burner caps and grates on the cooktop.