Whirlpool W10200946A Mobile Home - Additional Installation Requirements, Product Dimensions

Models: W10200946A

1 32
Download 32 pages 7.46 Kb
Page 4
Image 4
Mobile Home - Additional Installation Requirements

Use an insulated pad or ¼" (0.64 cm) plywood under range if installing range over carpeting.

IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.

In Canada, the installation of this range must conform with the current standards CAN/CSA-A240 - latest edition, or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

Product Dimensions

D

A

E

B

C

A. 36" (91.4 cm)

B.29⁷⁄₈" (75.9 cm)

C.24¼" (61.6 cm)

D.25¾" (65.6 cm)

E.46¼" (117.5 cm)

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.

If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend beyond cabinet fronts by ½" (13.0 mm) minimum.

IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

B Mobile home installations require:D

C

A

E

H Product DimensionsG

J

I

F D

K

Cabinet Dimensions M B D L

NL

A.18" (45.7 cm) min. clearance upper side cabinet to countertop

B.13" (33.0 cm) max. upper cabinet depth

C.30" (76.2 cm) min. cabinet opening width

D.For minimum clearance to top of cooktop, see NOTE*.

E.30¹⁄₈" (76.5 cm) min. opening width

F. This shaded area recommended for installation of electrical outlet. G. This shaded area recommended for installation of rigid gas pipe.

H. 2" (5.1 cm) min. countertop space to side wall or other combustible material

I. 24" (61.0 cm) J. 10" (25.4 cm) K. 8" (20.3 cm)

L. 5" (12.7 cm) M. 2" (5.1 cm) N. 3" (7.6 cm)

*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.